Fp2621 idv controls, Warn ing – Monessen Hearth IDV SERIES IDV380NVC User Manual
Page 5

57D0016
IDV380/IDV490 Fireplace Insert
5
FP2621
IDV controls
PRODuCt FeAtuReS
•
This appliance has been certified for use with
either natural or propane gas. Refer to the
appropriate data plates.
•
This appliance is not for use with solid
fuels.
•
The appliance is approved for bedroom or
bedsitting room installations.
•
The appliance must be installed in accor-
dance with local codes if any. If none exist
use the current installation code. ANSI
Z3.1/NFPA 54 in the USA, CSA B149 in
Canada.
•
The appliance must be properly connected
to a venting system.
PRODuCt SPeCiFiCAtiONS
Piezo Igniter
Figure 1 -
IDV Series Fireplace Insert
Optional
Remote
Receiver
Blower Knob
ON/OFF Switch
OFF/Pilot/ON
Knob
HI/LO Knob
Gas Shut-Off
Valve
On/Off
Remote
Switch
FP61
W
ARN
iNG
this appliance may be installed in an
aftermarket*, permanently located,
manufactured home, where not prohibited
by local codes
*Aftermarket: Completion of sale, not for purpose of resale,
from the manufacturer.
hiGh eleVAtiONS
Input ratings are shown in BTU per hour and are certified
without deration for elevations up to 4,500 feet (1,370
m) above sea level.
For elevations above 4,500 feet (1,370 m) in USA,
installations must be in accordance with the current
ANSI Z3.1/NFPA 54 and/or local codes having juris-
diction.
In Canada, please consult provincial and/or local authori-
ties having jurisdiction for installations at elevations
above 4,500 feet (1,370 m).
GAS PReSSuReS
Natural
Propane (LP)
Inlet Minimum
4.5” w.c.
11.0” w.c.
Inlet Maximum
10.5” w.c.
13.0” w.c.
Manifold Pressure
3.5” w.c.
10.0” w.c.
Max.input Min. input
Orifice
Model
Fuel
Btu/h
Btu/h
Size
IDV380NVC
Nat.
30,500
0,500
#35
IDV380PVC
LP
8,000
,000
#53
IDV490NVC
Nat.
40,000
6,500
#30
IDV490PVC
LP
37,500
9,000
#50
GAS SPeCiFiCAtiONS & ORiFiCe SiZe
The IDV Series gas inserts are equipped with a variable
speed output gas control.
NOte: IDV Series gas inserts operate without any elec-
trical supply. Blower must be attached to 110/10V AC.