beautypg.com

Fp2621 idv controls, Warn ing – Monessen Hearth IDV SERIES IDV380NVC User Manual

Page 5

background image

57D0016

IDV380/IDV490 Fireplace Insert

5

FP2621
IDV controls

PRODuCt FeAtuReS

This appliance has been certified for use with

either natural or propane gas. Refer to the
appropriate data plates.

This appliance is not for use with solid

fuels.

The appliance is approved for bedroom or

bedsitting room installations.

The appliance must be installed in accor-

dance with local codes if any. If none exist
use the current installation code. ANSI
Z3.1/NFPA 54 in the USA, CSA B149 in
Canada.

The appliance must be properly connected

to a venting system.

PRODuCt SPeCiFiCAtiONS

Piezo Igniter

Figure 1 -
IDV Series Fireplace Insert

Optional
Remote
Receiver

Blower Knob

ON/OFF Switch

OFF/Pilot/ON
Knob

HI/LO Knob

Gas Shut-Off
Valve

On/Off
Remote
Switch

FP61

W

ARN

iNG

this appliance may be installed in an
aftermarket*, permanently located,
manufactured home, where not prohibited
by local codes

*Aftermarket: Completion of sale, not for purpose of resale,
from the manufacturer.

hiGh eleVAtiONS

Input ratings are shown in BTU per hour and are certified
without deration for elevations up to 4,500 feet (1,370
m) above sea level.
For elevations above 4,500 feet (1,370 m) in USA,
installations must be in accordance with the current
ANSI Z3.1/NFPA 54 and/or local codes having juris-
diction.
In Canada, please consult provincial and/or local authori-
ties having jurisdiction for installations at elevations
above 4,500 feet (1,370 m).

GAS PReSSuReS

Natural

Propane (LP)

Inlet Minimum

4.5” w.c.

11.0” w.c.

Inlet Maximum

10.5” w.c.

13.0” w.c.

Manifold Pressure

3.5” w.c.

10.0” w.c.

Max.input Min. input

Orifice

Model

Fuel

Btu/h

Btu/h

Size

IDV380NVC

Nat.

30,500

0,500

#35

IDV380PVC

LP

8,000

,000

#53

IDV490NVC

Nat.

40,000

6,500

#30

IDV490PVC

LP

37,500

9,000

#50

GAS SPeCiFiCAtiONS & ORiFiCe SiZe

The IDV Series gas inserts are equipped with a variable
speed output gas control.
NOte: IDV Series gas inserts operate without any elec-
trical supply. Blower must be attached to 110/10V AC.

This manual is related to the following products: