beautypg.com

Fp2629 flex vent, Fp2630 attach flex vent, Fp2631 pull excess vent – Monessen Hearth IDV SERIES IDV380NVC User Manual

Page 14: Fp2632 place insert

background image

14

57D0016

IDV380/IDV490 Fireplace Insert

VeNtiNG iNStAllAtiON

MANiFOlD ReMOVAl AND iNStAllAtiON

The manifold is shipped attached to insert. It may be
removed to allow tight installation. Manifold may be loos-
ened and rotated for desired
pipe location.
1. Remove brick liner and

baffle.

. Remove manifold. Place

manifold in fireplace.

3. Route flex vent through chim-

ney from above. Figure 10.
Leave an extra 3" (914 mm)
at the top.

FP2629
flex vent

Flex
Vent

Chimney

Manifold

Bracket
Nut

FP69

Figure 10 -
Place Manifold into Fireplace

FP2630
attach flex vent

Extra 3"

Chimney

Flex
Vent

Manifold

FP630

Figure 11 -
Attach Flex Vent to Manifold

4. Attach flex vent to

manifold. Figure 11.
Seal with silicone
and attach with
screws.

FP2631
pull excess vent

Excess
Flex
Vent

Chimney

Slack in
Flex Vent

Manifold

FP63

Figure 12 -
Pull on Excess Flex Vent

5.

Place mani-

fold in an upright
position. Pull on
excess vent. Figure
12.
Temporarily
attach flex vent
to top of chimney.
Leave some extra
slack in flex vent.

FP2632
place insert

Vent
Termination

Chimney

Excess Slack
Take out of Flex
Vent

Manifold

Bracket

Nut

FP63

Figure 13 -
Slide Insert into Place

Insert

6. Slide insert into place.

Guide the manifold
over the insert until it
is fully in place. Figure
13

7. Remove any slack from

flex vent. Attach mani-
fold to insert. Figure
13

8. Remove any excess

slack in flex line. Attach
v e n t t e r m i n a t i o n .
Figure 13

9. Replace baffle and

brick liner.

This manual is related to the following products: