beautypg.com

System assembly – GE GXRV10ABL01 User Manual

Page 17

background image

Consumer Support

Tr

oubleshooting T

ips

Operating Instructions

Safety Instructions

Installation Instructions

17

Reverse Osmosis System Assembly and Storage Tank Installation

1.

Hold the Reverse Osmosis assembly up to the wall surface where you will install it. Mark locations
for the hanger washers and screws.

2.

Fasten the hanger washers to the wall surface. Wood screws are included for fastening to a wood
surface. Provide other screws as needed.

3.

Hang the Reverse Osmosis assembly on the hanger washers.

4.

Connect the tubing to the storage tank: Run the length of 3/8

″ tubing (marked “STORAGE TANK”)

from the tee fitting on the Reverse Osmosis module to the tank shutoff valve. Use Teflon Tape

TM

to

prevent leaks.

Fig. 6A.

Storage tank

Hanger
washer

(2)

Screw

(2)

10″

2

″ minimum clearance for

changing cartridges

Fig. 6B.

RO faucet

Reverse Osmosis

system

Cold
water
supply

Sink
p-trap

Storage tank

*For drain line options see Filtration Drain Connection Installations section.