beautypg.com

GarrettCom Magnum 3000 User Manual

Page 8

background image

Magnum 3000 Stackable Hubs Installation and User Guide (07/06)

1

www GarrettCom com

.

.

1.0

Specifications - Magnum 3024, Magnum 3012

Performance

Data Rate:

10 Mbps

RPM Partitioning:

Enforced after 32 consecutive collisions

RPM Reconnect:

Occurs after 512 bits error-free reception

BPM Auto-Learning Address List:

256 nodes capacity

BPM Filtering and Forwarding Rate:

14,880 pps max.

Maximum Ethernet Segment Lengths

DTE (AUI Drop Cable)

- 50 m (164 ft)

10BASE-T (twisted pair)

- 100 m (328 ft)

Shielded twisted pair

- 150m (492 ft)

10BASE2 ThinNet (BNC)

- 185 m (607 ft)

10BASE5 ThickNet

- 500 m (1,640 ft)

FOIRL multi-mode Fiber optic

- 1 km (3,281 ft)

10BASE-FL multi-mode Fiber optic

- 2 km (6,562 ft)

Single-mode Fiber optic

- 10 km (32,810 ft)

Network Standards

Ethernet V1.0/2.0 IEEE 802.3: 10BASE-T, 10BASE5,

10BASE2, 10BASE-FL & FOIRL, and DTE

Operating

Environment

Ambient Temperature:

25ºF to 120ºF (-5ºC to 50ºC)

Storage

Temperature:

-40ºF to 185ºF (-40ºC to 85ºC)

Ambient Relative Humidity: 5% to 95% (non-condensing)

Altitude: -200 to 13,000 Ft. (-60 to 4000 m)

Conformal coating option: Request quote

Port Connector Types

RJ-45:

Shielded, 8-Pin Female (Note: Shielded 10BASE-T

connectors accept either unshielded or shielded wiring

plugs for standard twisted pair media wiring.)

Fiber Optic:

ST (Twist-Lock Connector, for single and multi-mode)

Fiber Optic: SC (Snap-in Connector, for multi-mode fiber cables only)

ThinNet:

BNC

AUI:

D-Sub 15-Pin Female (with slide lock)

DTE:

D-Sub 15-Pin Male (with lock posts)

Power Supply (Internal)

AC Power Connector: IEC-type, male recessed, rear of chassis

Input Voltage: 100 - 240 vac (auto-ranging)

Input Frequency: 47 - 63 Hz (auto-ranging)

Power Consumption: Model 3024: 18 watts typical; 30 watts max,

Model 3012: 10 watts typical; 20 watts max,

3000-AGT: 9 watts typical; 20 watts max,