If this error occurs frequently contact your dealer
**)
Other problems which initiate this error are:
- The weighbinDumpTime too short
- Weighbin valve touches the material when mixerchamber is full
When the second problem occurs the position of the mixerchamber-sensor must be set
lower. This actions affects the total production capacity of your system.
***) Through a too short dispense valve opening time, the machine could think that there is
no material in the hopper. There are three possible reasons for this.
-1 dispense accuracy is too narrow
-2 dispense speed is too high
-3 number of dispense attempts is too low solutions:
-1 increase dispense accuracy (§ 3.5.2)
-2 adjust speed in recipe (§ 3.2.2)
-3 increase number of attempts (§ 3.5.2)
An error message on the terminal must be confi rmed by pressing the
terminal stores all error messages these can be displayed by the menu (F1) ‘controller / alarm
history’. This screen shows the last 256 errors and the number of times the error occurred. The
error-list can de cleared by pressing (F2) option button and choose clear, with this button it is
also possible to print a report of alarms, select ‘print alarm history’ and push