GE FGB-M05 User Manual
Page 31
Rev. May 2001
GraviMaster-FGB-M05 (S)
Page 30
Gravimetric
Blender
OPERATING AUTO[ ] [ ] [ ]
STATUS:[0] FGB#00: (No name) STATUS OPERATING MODE: AUTOMATIC
PRODUCTION
STATUS]
Production mode :
CONTINUE
Dispense mode: GRAVIMETRIC
Name:
PIR-HOUSING
Mix mode
:
PULSE
Recipe
CRATES
YELLOW
[current]
[previous]
[total]
H# Type
Recipe Requested
Dispensed Recipe
Dispensed Recipe Dispensed
1 REG
[ 20.0] 400.0
20.0
400.0
20.0 1600
2 NAT
[ 1.0] 1523.8
1.0
1523.8
1.0 6095
3 ADD
[ 5.0] 76.2
5.0
76.2
5.0 305
4
5
6
7
8
9
10
11
12
totals
[ACCEPT] [UNDO CHANGES] 0.1 2000.0 8000
Produced weight: 82000
F1Menu
F2Option
F3 F4Node F5Start
F6Stop
F7Pauze
F8Cont.
During production it is possible to change the recipe without a change of the current recipe.
The recipe can be changed in the production-screen by selecting a fi eld (arrow-keys). Next
enter a new value and press
controller uses the new values at the start of a new batch.
3.3.2 Material usage screen
The material usage screen menu (F1) ‘production / material usage’ displays the total
quantity of material witch is used ordered by hopper number. The quantities which are stored
doesn’t depend on the current recipe. The material usage screen is erased from memory by
one of the following actions:
* Command given by the operator
* After a operator prints the screen.
This is possible by using option-key (F2) and selecting the option you require and pressing
Other values witch are stored in the material usage screen are: date of the last erase-action,
number of batch-cycles and production speed (kg/hour).