beautypg.com

Test electrode resistance – Graco Inc. 244581 User Manual

Page 32

background image

Electrical Tests

32

309293K

Test Electrode Resistance

1.

Prepare the gun for service as instructed on page
41.

2.

Insert a conductive rod (B) into the gun barrel
(removed for the power supply test) and against the
metal contact (C) in the front of the barrel.

3.

Measure the resistance between the conductive rod
(B) and the electrode (29). The resistance should be
20-30 megohms. See F

IG

. 19..

4.

If in range, refer to Electrical Troubleshooting on
page 39 for other possible causes of poor perfor-
mance, or contact your Graco distributor.

5.

Remove the electrode (29), page 43. Measure the
resistance between the contact (E) and the elec-
trode wire (F). The resistance should be 20-30
megohms. If out of range, replace the electrode.
See F

IG

. 20..

6.

Make sure the metal contact (C) in the barrel, the
nozzle contact ring (7a, F

IG

. 21.), and the electrode

contact (E) are clean and undamaged.

Fig. 19. Test Electrode Resistance

Fig. 20. Electrode

Fig. 21. Nozzle Conductive O-Ring

ti1499a

B

29

C

ti1548a

F

29

E

ti1513a

7a

This manual is related to the following products: