User instructions, Riva, Riva avanti – Stovax PM235 RV66AVC User Manual
Page 8: Running the appliance
8
USER INSTRUCTIONS
5.6 Burning Solid fuel (Not applicable for Riva 76):
• Set air controls, See Diagram
PRIMARY AIR CONTROL
AIRWASH AIR CONTROL
PR7003
PR7034
RIVA
PRIMARY AIR CONTROL
AIRWASH AIR CONTROL
PR7047
PR7048
RIVA AVANTI
Open Fully
Open Fully
Open 25%
Open 25%
5.7 When the fire becomes established reduce the Airwash air
control
to approximately 25% open and control the burn
rate using the Primary air control only.
5.8 De-ash the fire bed before re-fuelling, see Ash Removal,
Section 7.
• Open the Primary air control fully to establish a glowing
bed before adding new fuel
• Burn new fuel at high output for a few minutes before
adjusting the Primary air control to the desired setting
• Refuel little and often for clean, efficient burning.
5.9 Experience establishes control settings to suit personal
preferences
5.10 Do not burn large amounts of fuel with the Primary Air
Control
on low settings for long periods of time. This
reduces the glass cleaning effect of the air wash and causes
tars and creosotes to build-up in the appliance and flue
system.
5.11 When in use, burning the appliance at high output for a
short period also reduces tars and creosote.
5.12 You must burn only anthracite or smokeless fuels
suitable for use in closed appliances
.
5.13 Do not burn bituminous coal, ‘petro-coke’ or other
petroleum based fuels as this invalidates the product
guarantee
.
Do not load fuel above the log guard and the secondary
combustion inlets at the back of the firebox.
See Diagram 7
5. RUNNING THE APPLIANCE
5.1 Burning Wood:
• Close the Primary air control (multi-fuel versions only)
and use the Airwash to control the burn rate when
appliance is at operating temperature, see Diagram
PRIMARY AIR CONTROL
AIRWASH AIR CONTROL
PR7003
PR7034
RIVA
PRIMARY AIR CONTROL
AIRWASH AIR CONTROL
PR7047
PR7048
RIVA AVANTI
Adjust
Adjust
Close
Close
Ashpan
Tool
• Wood burns best on a bed of ash
• Rake the embers evenly over the fire bed and open the
Airwash control
fully for a few minutes before re-fuelling
5.2 Burn new logs at high output for a few minutes before
adjusting the Airwash control. Refuel little and often for
clean, efficient burning.
5.3 Experience establishes settings to suit personal preferences.
5.4 Do not burn large amounts of fuel with the Airwash control
closed for long periods of time. This reduces the glass
cleaning effect and causes tars and creosotes to build-up in
the appliance and flue system.
5.5 When in use, burning the appliance at high output for a
short period also reduces tars and creosote.