Page 20
20
2.1 Additional ventilation is required to comply with the
requirements of the Building Regulations. This must be
provided using a permanently open air vent, of the size
listed, which is positioned so that it is not liable to be
blocked both inside and outside the building.
2.2 Extractor fans or cooker hoods must not be placed in the
same room or space as this can cause the appliance to emit
fumes into the room.
2.3 If any of these checks reveal problems do not proceed
with the fitting of the appliance until they have been
rectified.
2. ADDITIONAL VENTILATION
PRE-INSTALLATION CHECKS
mm2
NONE
1650mm2 1650mm2 1650mm2 2475mm2
Additional Ventilation cm2
NONE
16.5cm2
16.5cm2
16.5cm2 24.75cm2
in2
NONE
2.56in2
2.56in2
2.56in2
4.00in2
Riva
40
Riva
55
Riva
66
Riva
66
Avanti
Model
Riva 40-RV 40/RV40B
Riva 55-RV 55/RV55B
Riva 66-RV 66/RV66B
Riva 66 Avanti-RV66 AVC
Riva 66-RV76/RV76B
Riva
76