beautypg.com

Maintenance and servicing, 12a. adjusting door catch - riva, Fitting a new door seal – Stovax PM235 RV66AVC User Manual

Page 30

background image

30

• Squeeze a generous bead of fresh Stovax Thermic Seal

glue into the rope locating groove

• Press the new Stovax rope into the locating groove,

placing the joint in the middle of the lower edge of the

door

• Refit the door and close the door to apply pressure to the

new rope

• Leave the appliance closed for at least 12 hours before

lighting the appliance and using at a low output for

approximately one day

11.2 Using the appliance with a damaged door seal can cause

dangerous fumes to enter the room, or the appliance to

over fire, resulting in damage.

12A. ADJUSTING DOOR CATCH - RIVA

12a.1 To maintain the safe use of your Riva, you may need to

adjust the door catch to ensure safe correct closing of the

door.

To Complete this operation:

• Open the main firedoor to give access to the fixed part of

the door catch as shown in diagram 7.

• Using a 2.5mm A/F hexagon key loosen the 2 fixing

screws, as shown in diagram 7

• Reposition the catch block to achieve a correct fit

This may need a trial and error approach to find the correct

position.

12a.2 If the door feels loose after correcting the catch operation

the door rope seal is worn and requires replacement, as

detailed in section 7.

Fixing Screws

3

Riva 66 Avanti see 3B

• Lay the door face down on a soft flat surface, to protect

the paintwork and glass

• Remove the old door rope seal and scrape old glue from

the locating groove

Clean with a dry cloth to remove dust and debris.

• Remove the glass clip fixing screws with a 2.5A/F

hexagon key

The old glass can then be lifted clear of the door (Note how

the edge sealing tape is fixed).

• Dispose of the old glass safely.

• Clean and re-paint the rear of the door if required

Clean the screws with light oil and coat with high

temperature anti-seize grease, this will aid future removal.

• Fit the edge sealing tape to the new glass and place the

glass into position in the door

• Place the door frame/trim back into position and refix

with the cleaning fixing screws

Do not over tighten the clips as this could break the glass.

• Squeeze a generous bead of fresh Stovax Thermic Seal

glue into the rope locating groove

Do not glue over the screw heads

.

• Press the new Stovax door sealing rope into the locating

groove, placing the joint in the middle of the lower edge of

the door

• Refit the door on to the appliance and close the door to

apply pressure to new rope

Leave the appliance closed for at least 12 hours before

lighting the appliance and use at a low output for

approximately one day.

10.2 Fit only original Stovax ceramic glass, which is suitable to

use in high temperature applications.

10.3 Using the appliance with a damaged door glass could cause

dangerous fumes to enter the room, or the appliance to

over fire, resulting in damage.

11. FITTING A NEW DOOR SEAL

11.1 To maintain the safe use of your appliance you need to

replace damaged or worn door sealing rope. To complete

this operation:

• Remove the door from the appliance, by opening 25mm,

and lifting the door free of the hinge blocks

• Lay the door face down on a soft flat surface, to protect

the paintwork and glass

• Remove the old rope and scrape old glue from the

locating groove

Clean the locating groove with a clean dry cloth to remove

all old dust and debris.

MAINTENANCE and SERVICING

This manual is related to the following products: