Installation instructions, Baffle removal (all) – Stovax PM235 RV66AVC User Manual
Page 23
23
INSTALLATION INSTRUCTIONS
5
• Remove the fixing screws and lift the ashpit door clear of
the appliance
4.2 The replacement of the system is the reverse of the
previous operations.
5. BAFFLE REMOVAL (ALL)
(Tools required – None)
The Riva MF is fitted with a twin baffle system, consisting of
upper and lower baffles, Diagram 6.
6
PR7017
Upper Baffle
Lower Baffle
5.1 Remove the log guard from the Riva MF to give access to
the firebox.
5.2 First remove the Lower Baffle, see diagram 7:
• Lift the front edge to unhook it from the support bars
• Pull the baffle forward to disengage the rear edge from
the location above air inlet holes
• Rotate the baffle to remove from the firebox through the
door opening
5.3 Second remove the Upper Baffle, see diagram 8:
• Pull forward to disengage it from the hanging points at the
top of the firebox
7
• Rotate the baffle to remove from the firebox through the
door opening
8
5.4 The replacement of the system is the reverse of the previous
operations.
5.5 Do not modify the baffle