Technical specification, Standard features, Packing list – Stovax PM235 RV66AVC User Manual
Page 13: Riva mf cassette
13
TECHNICAL SPECIFICATION
STANDARD FEATURES
• Primary air (under grate air for full multifuel use)
• Airwash (for woodburning/ clean glass)
• Pre-set secondary air control (to ensure complete
burning of flue gases)
• Riddling grate system for clean de-ashing
• Stainless steel ashpan
• Removable door handle
• Interchangeable trim / frame options
• Pre-drilled convection air duct connection points (not
Riva 40)
• Optional fan convection kit - must be fitted before
installation only (not Riva 40)
• Spacer frame kit - to suit 350mm deep opening
(Riva 66 and 76 only)
PACKING LIST
• User Instructions
• Installer Instructions
• Guarantee card
• Accessory catalogue
• Pair leather stove gloves
• Fixing kit (2 x rawl plugs + 2 x coach screws)
• 2.5mm A/F Hex socket key
• 4mm A/F Hex Socket Key
• 5mm A/F Hex Socket Key
• Door tool
• Riddling tool
Model
Riva 40-RV 40/RV40B
Riva 55-RV 55/RV55B
Riva 66-RV 66/RV66B
Riva 66 Avanti-RV66AVC
Riva 76/RV76
Nominal Heat Output
Wood
kW
4.9
8
8
8
9.5
Solid Fuel
kW
4.9
8
8
8
N/A
Flue Draught at Nominal Heat
All Fuels
mm
1.5
1.5
1.5
1.5
1.5
inch Wg
0.05
0.05
0.05
0.05
0.05
Flue Gas Mass Flow
Wood
g/s
5.8
8.3
7.4
7.4
10.8
Solid Fuel
g/s
5.2
9.9
8.1
8.1
N/A
Flue Gas Temperature at Spigot/Socket
Wood
°C
444
492
388
388
406
Solid Fuel
°C
444
492
388
388
N/A
Flue Outlet Size
mm
128
128
150
150
150
inch
5
5
6
6
6
Weight
kg
70
90
101
121
125
Recommended Fuel
Wood
Seasoned wood (less than 20% moisture content)
Solid Fuel
Briqette smokeless fuel suitable for closed appliances
(Ancit - Phurnacite - Taybrite - Homefire ovals)
As tested to the requirements of EN 13229:2001 for intermittent operation
Riva
40
Riva
55
Riva
66
Riva
66
Avanti
Riva
76
RIVA MF CASSETTE