Installation instructions, Removal of the log guard, 3a. door removal (riva) – Stovax PM235 RV66AVC User Manual
Page 22: 3b. door removal (riva avanti), Ashpan door removal (riva)
22
INSTALLATION INSTRUCTIONS
2. REMOVAL OF THE LOG GUARD
2.1 To remove the Log guard:
• Lift Log Guard clear of the supporting brackets
• Rotate to clear the sides of the door opening.
Do not use appliance without the log guard in position.
3A. DOOR REMOVAL (RIVA)
(Tools required – None)
3a.1 To remove the door from the Riva MF:
• Open the door by approximately 25mm
• Lifting the door free of the hinge blocks on the left of the
door
• Lie the door face down on a soft flat surface, to protect
the paintwork and glass
3a.2 Take care to protect the top left hand corner of the door to
avoid damage to the paintwork.
3B. DOOR REMOVAL (RIVA AVANTI)
(Tools required - Large flat-blade screwdriver)
3b.1 To remove the door from the Riva Avanti:
• Remove the hinge pin
Unscrewing the hinge pin from the body of the Riva and
pulling the pin out of the hinge blocks does this.
• Support the weight of the door before removing the pin
The door should be kept in the closed position when the
pin is removed.
• Release the door catch to lift the door clear of the hinge
blocks
3b.2 Lie the door on a soft flat surface, to protect the glass and
paintwork.
3b.3 Replace the door in the reverse order from removal. Do not
hang the door from the catch only when replacing, as this
could damage the catch mechanism.
3b.4 Care should be taken to fully support the weight of the door
during the removal and replacement, as the door assembly
is heavy.
4. ASHPAN DOOR REMOVAL (RIVA)
(Tools required – 2.5mm A/F Hex socket key)
4.1 To remove the ashpan door from the appliance,
• Lower the door to expose the hinge fixing screws (2 each
hinge) Diagram 5
2
Fire Cement
PR7243
Adaptor supplied by flue
liner manufacturer.
3
1.6 If the Riva MF is installed on an unlined, masonry flue:
• Fit a non-combustible closure plate to locate the first
section of single wall flue pipe from the Riva MF to the old
system
• Make the connection as with a flue liner system
Do not connect the system into large voids that could exist
in older chimney systems. If this is the case consider using
a flue lining system to improve the Riva MF operation. See
diagram 16
PR7244
Closure Plate
Ridged Flue Pipe
4