beautypg.com

GarrettCom Magnum 20X User Manual

Page 14

background image

Module (RPM) to provide either 10BASE2, 10BASE5, 10BASE-FL, FOIRL, or 10BASE-T

connectivity. The individual RPMs are used for one Ethernet segment each, and provide full

IEEE 802.3 repeater functionality supporting a full length segment. Individual RPMs are

equipped

with a single media interface

connector. Any RPM can be

installed in either slot of the

Magnum 200X chassis.

Figure 2.2.1: Magnum 200X

To simplify media connections, each media interface port is accessible from the

front of the unit. All LEDs common to the 200X unit and all individual port LEDs are

front-mounted. No rear access is required except for the AC power cord.

The internal power supply is auto-ranging to handle any AC power type

worldwide. Power input may range from 90 to 260 vac, with a frequency rating of 47 to 63

Hz. The unit is equipped with a rear mounted IEC-type recessed male AC power

connector. (When shipped for use in areas other than 115 vac, a power cord will not be

included). The 200X unit is convection-cooled for silent operation.

The Magnum 200X base unit features Power (PWR), Receive (RX), Collision

(COL), and Jabber (JAB) LED status indicators located in the front of the unit. These

LEDs provide a visual assessment of the operational condition and aggregate network

activity at the unit, and are in addition to the LEDs on each individual RPM.

2.3

Magnum 200X - Repeater Port Modules (RPMs)

For standard 200X models, there is an option of four different Repeater Port

eu

Magnum 200X

GARRETT

PWR RX COL JAB