beautypg.com

Cph120 v m, Iring, Iagram – Goodman Mfg CPH COMMERCIAL SS-CPH90-150 User Manual

Page 31: Odles, Cont, Roduct, Pecifications, Arning

background image

30

www.goodmanmfg.com

SS-CPH90-150

SS-CPH90-150

www.goodmanmfg.com

31

P

roduct

S

PecificationS

P

roduct

S

PecificationS

w

iring

d

iagram

— CPH120 V m

odles

(

Cont

.)

Wiring is subject t

o chang

e. Alw

ay

s

re

fer

to the wiring diagr

am or the

unit

for the mos

t up-t

o-da

te

wiring.

W

arning

High

Volt

ag

e:

Disc

onn

ect

all

po

w

er

be

for

e

ser

vicing

or

in

st

alling

this

unit.

Multiple

po

w

er

sour

ces

ma

y

be pr

esen

t. F

ailur

e

to do

so ma

y

cause pr

operty

damag

e,

per

sonal

injur

y,

or dea

th.

R

BC2

R

HVDR

RVC2

SEE UNIT RATING PLATE FOR TYPE AND SIZE

5

OF OVER CURRENT PROTECTION

4

BLOWER CONTACTOR

COMPRESSOR CONTACTOR

CONDENSER MOTOR

CONDENSER MOTOR CONTACTOR

COMPRESSOR

DEFROST CONTROL

DEFROST THERMOSTAT

ECONOMIZER

ELECTRONIC BLOWER TIME DELAY

EVAPORATOR MOTOR RELAY

RELAY

EVAPORATOR MOTOR

FAN CAPACITOR

EQUPIMENT GROUND

HIGH PRESSURE SWITCH

HIGH VOLTAGE DEFROST RELAY

LOW PRESSURE SWITCH

LOW VOLTAGE DEFROST RELAY

LOW VOLTAGE JUNCTION BOX

POWER DISTRIBUTION BLOCK

FEMALE PLUG / CONNECTOR

REVERSING VAVLE COIL

TERMINAL BLOCK (24V SIGNAL)

TRANSFORMER

LVDR

W2

R

DFT2

C

BC

CC

CM

CMC

COMP

DC

DFT

ECON

EBTD

EMR

R

EM

FC

GND

HPS

HVDR

LPS

LVDR

LVJB

PB

PLF

RVC

TB1

TR

6

COMPONENT LEGEND

R

R

208-240/460/575/3/60 0140L02292-A

G

NOTES:

1. REPLACEMENT WIRE MUST BE SAME SIZE AND

TYPE INSULATION AS ORIGINAL (AT LEAST 105°C)

USE COPPER CONDUCTOR ONLY.

2. USE COPPER CONDUCTORS ONLY

++ USE N.E.C. CLASS 2 WIRE

3. ECONOMIZER PLUG LOCATED IN THE RETURN AIR

COMPARTMENT. REMOVE MALE PLUG AND ATTACH

FEMALE PLUG TO THE ECONOMIZER ACCESSORY.

4. FOR TWO STAGE OPERATION REMOVE W1 TO W2

JUMPER WIRE.

EBTDR

CC1

TB1

HPS1

LPS1

LOW VOLTAGE

LINE VOLTAGE

FIELD WIRING

LOW VOLTAGE

OPTIONAL

HIGH VOLTAGE

FACTORY WIRING

HIGH VOLTAGE

CC2

C

W1

W2

G

Y1

O

R

GR GREEN

WIRE CODE

BL BLUE

PU PURPLE

PK PINK

WH WHITE

BK BLACK

RD RED

BR BROWN

OR ORANGE

YL YELLOW

YL/PK YELLOW WITH

PINK STRIP

BL/PK BLUE WITH

PINK STRIP

S1

S2

CMC

CMC

CM2

T2

CC2

T3

T1

COMP2

CC2

T1

CC2

T2

CMC

CC1

L2

T3

COMP1

F

SUPPLY VOLTAGE

CM1

L1

CC1

T1

C

CC1

L3

208-240/440/575/3/60

T2

TR

24V

8

7

9

OR

O

O

BL

Y1

GR

PK

TB1

W1

R

G

C

R

2 STAGE COOLING

Y/Y2

YL

G

C

WH

Y2

Y1

STAT

W1

RD

THERMOSTAT

FIELD WIRING

W2

BR

W2

SEE NOTE 4

NO

NC

PLF2

9

7

8 5

6

4

3
2
1

SEE NOTE 3

O

SSHR

SECOND STAGE HEATER RELAY

BC2

EM

CB2

BC2

HIGH SPEED

LOW SPEED

CB2

BC1

CB1

BC1

BC1

BR1

BR1

BR2

BR3

BR2

BR3

CCR1

CCR2

LPS2

HPS2

CB1

EBTDR

BLOWER RELAY

CIRCUIT BREAKER

COMPRESSOR CONTACTOR RELAY

BR

CB

CCR

F

C

BC2

CB2

BC1

CB1

4

5

2

4

5

2

4

5

2

DFT1

R

Y2

Y

R

EBTDR

BC2

R

HVDR

Y

SEE UNIT RATING PLATE FOR TYPE AND SIZE

5

OF OVER CURRENT PROTECTION

4

BLOWER CONTACTOR

COMPRESSOR CONTACTOR

CONDENSER MOTOR

CONDENSER MOTOR CONTACTOR

COMPRESSOR

DEFROST CONTROL

DEFROST THERMOSTAT

ECONOMIZER

ELECTRONIC BLOWER TIME DELAY

EVAPORATOR MOTOR RELAY

RELAY

EVAPORATOR MOTOR

FAN CAPACITOR

EQUPIMENT GROUND

HIGH PRESSURE SWITCH

HIGH VOLTAGE DEFROST RELAY

LOW PRESSURE SWITCH

LOW VOLTAGE DEFROST RELAY

LOW VOLTAGE JUNCTION BOX

POWER DISTRIBUTION BLOCK

FEMALE PLUG / CONNECTOR

REVERSING VAVLE COIL

TERMINAL BLOCK (24V SIGNAL)

TRANSFORMER

LVDR

W2

DFT

R

DFT2

C

BC

CC

CM

CMC

COMP

DC

DFT

ECON

EBTD

EMR

R

EM

FC

GND

HPS

HVDR

LPS

LVDR

LVJB

PB

PLF

RVC

TB1

TR

6

COMPONENT LEGEND

R

R

C

208-240/460/575/3/60 0140L02292-A

P

L

F

1

G

NOTES:

1. REPLACEMENT WIRE MUST BE SAME SIZE AND

TYPE INSULATION AS ORIGINAL (AT LEAST 105°C)

USE COPPER CONDUCTOR ONLY.

2. USE COPPER CONDUCTORS ONLY

++ USE N.E.C. CLASS 2 WIRE

3. ECONOMIZER PLUG LOCATED IN THE RETURN AIR

COMPARTMENT. REMOVE MALE PLUG AND ATTACH

FEMALE PLUG TO THE ECONOMIZER ACCESSORY.

4. FOR TWO STAGE OPERATION REMOVE W1 TO W2

JUMPER WIRE.

EBTDR

CC1

DC

TB1

HPS1

LPS1

LOW VOLTAGE

LINE VOLTAGE

FIELD WIRING

LOW VOLTAGE

OPTIONAL

HIGH VOLTAGE

FACTORY WIRING

HIGH VOLTAGE

CC2

C

W1

W2

G

Y1

TO THERMOSTAT

O

R

++

GR GREEN

WIRE CODE

BL BLUE

PU PURPLE

PK PINK

WH WHITE

BK BLACK

RD RED

BR BROWN

OR ORANGE

YL YELLOW

YL/PK YELLOW WITH

PINK STRIP

BL/PK BLUE WITH

PINK STRIP

S1

S2

CMC

CMC

FC2

CM2

T2

CC2

T3

T1

COMP2

CC2

T1

CC2

T2

CMC

CC1

L2

T3

COMP1

F

SUPPLY VOLTAGE

CM1

L1

CC1

T1

C

CC1

L3

208-240/440/575/3/60

T2

TR

24V

8

7

9

OR

O

O

BL

Y1

GR

PK

TB1

W1

R

G

C

R

2 STAGE COOLING

Y/Y2

YL

G

C

WH

Y2

Y1

STAT

W1

RD

THERMOSTAT

FIELD WIRING

W2

BR

W2

SEE NOTE 4

SSHR

NO

NC

9

7

8 5

6

4

3
2
1

SEE NOTE 3

O

SSHR

SECOND STAGE HEATER RELAY

T2

BC2

EM

CB2

BC2

HIGH SPEED

LOW SPEED

CB2

BC1

CB1

BC1

BC1

BR1

BR1

BR2

BR3

BR2

BR3

CCR1

CCR2

CCR1

CCR2

LPS2

HPS2

CB1

EBTDR

BLOWER RELAY

CIRCUIT BREAKER

COMPRESSOR CONTACTOR RELAY

BR

CB

CCR

F

C

BC2

CB2

BC1

CB1

4

5

2

4

5

2

4

5

2

DFT1

R

Y2

Y

DR

NO

DR

NC

TR

24V

C

TR

24V

RVC1

FC1

5. MOVE WIRE(S) TO APPROPRIATE INPUT

VOLTAGE TERMINAL ON TRANSFORMER.

C

SEE NOTE 5

SEE NOTE 5