Product specs — 7½ tons, 7½ t, Roduct – Goodman Mfg CPH COMMERCIAL SS-CPH90-150 User Manual
Page 3: Pecifications
2
www.goodmanmfg.com
SS-CPH90-150
SS-CPH90-150
www.goodmanmfg.com
3
P
roduct
S
PecificationS
P
roduct
S
PecificationS
P
roduct
S
PecificationS
— 7½ t
onS
CPH090
***3B***A*
CPH090
***4B***A*
CPH090
***7B***A*
Cooling Capacity
Total BTU/h
90,000
90,000
90,000
Sensible BTU/h
65,700
65,700
65,700
EER / IEER
11.5 / 11.5
11.5 / 11.5
11.5 / 11.5
Decibels
83
83
83
AHRI Reference #s
5104781
5104781
5104781
Heating Capacity
BTU/h / COP (47° F)
90,000 / 3.4
90,000 / 3.4
90,000 / 3.4
BTU/h / COP (17° F)
55,000 / 2.4
55,000 / 2.4
55,000 / 2.4
Evaporator Motor / Coil
Motor Type
Belt Drive
Belt Drive
Belt Drive
Indoor Nominal CFM
3,000
3,000
3,000
Indoor Motor FLA (Cooling)
7.8
3.9
2.5
Horsepower - RPM
2.0 - 1725
2.0 - 1725
2.0 - 1725
Piston Size (Cooling)
0.076
0.076
0.076
Filter Size
16" x 24" x 2"
16" x 24" x 2"
16" x 24" x 2"
Drain Size (NPT)
¾"
¾"
¾"
R-410A Refrigerant Charge: Cir #1 / #2 (oz.)
215 / 215
215 / 215
200 / 200
Evaporator Coil Face Area (ft²)
10.2
10.2
10.2
Rows Deep / Fins per Inch
4 / 16
4 / 16
4 / 16
Belt Drive Evap Fan Data
# of Wheels (D x W)
1 (15" x 12")
1 (15" x 12")
1 (15" x 12")
Motor Sheave / Blower Sheave
VL40 / AK74
VL40 / AK74
VL40 / AK74
Belt
AX51
AX51
AX51
Condenser Fan / Coil
Quantity of Condenser Fan Motors
2
2
2
Horsepower - RPM
¼ - 1090
¼ - 890
¼ - 1075
Fan Diameter / # Fan Blades
22 / 4
22 / 4
22 / 4
Outdoor Expansion Device
0.052
0.052
0.055
Outdoor Nominal CFM
7,600
7,600
7,600
Face Area (ft²)
32.4
32.4
32.4
# Coils / Rows Deep - Fins per Inch
2 / 2 - 20
2 / 2 - 20
2 / 2 - 20
Piston Size (Heating)
0.052
0.052
0.055
Compressor
Quantity / Type / Stage
2 / Scroll / 1
2 / Scroll / 1
2 / Scroll / 1
Compressor RLA / LRA
13.1 / 83.1
6.1 / 41.0
4.4 / 33.0
Electrical Data
Voltage / Phase / Frequency
208-230 / 3 / 60
460 / 3 / 60
575 / 3 / 60
Indoor Blower HP / FLA
1.5 / 5.0
1.5 / 2.5
2 / 2.5
Outdoor Fan HP / FLA
¼ / 1.4
¼ / 0.8
¼ / 0.6
Total Unit Amps
36.9
17.7
12.5
Min. Circuit Ampacity¹
40
19
13.6
Max. Overcurrent Protection (amps)²
50
25
15
Entrance Power Supply & Control Voltage
Locating Dimple
Locating Dimple
Locating Dimple
Operating Weight (lbs)
1135
1135
1135
Ship Weight (lbs)
1175
1175
1175
¹ Wire size should be determined in accordance with National Electrical Codes. Extensive wire runs will require larger wire sizes.
² May use fuses or HACR-type circuit breakers of the same size as noted.
Notes
• Always check the S&R plate for electrical data on the unit being installed.
• When a factory-installed powered convenience outlet is installed in the equipment, the unit MCA (Min. Circuit Ampacity) will increase by 7.5A for
208/230V units, increase by 3.75A for 460V units, and by 3A for 575V units. The MOP (Max. Overcurrent Protection) device must be sized accordingly.