Nomenclature, Omenclature, Roduct – Goodman Mfg CPH COMMERCIAL SS-CPH90-150 User Manual
Page 2: Pecifications
2
www.goodmanmfg.com
SS-CPH90-150
SS-CPH90-150
www.goodmanmfg.com
3
P
roduct
S
PecificationS
P
roduct
S
PecificationS
N
omeNclature
C
P
H
090
030
3
B
*
*
*
A *
1
2
3
4,5,6
7,8,9
10
11
12
13
14
15 16
Revision Levels
Major & Minor
Brand
Factory-Installed Options
C
Commercial
X
No Options
A
Non-powered convenience outlet
Configuration
B
Powered convenience outlet
P
Packaged Unit
C
Low-ambient kit
D
Return air smoke detector
Application
E
Supply air smoke detector
C
Cooling
F
Non-powered convenience outlet;
G
Gas Heat
Low-ambient kit
H
Heat Pump
G
Non-powered convenience outlet;
Return air smoke detector
Nominal Gross Cooling Capacity
H
Non-powered convenience outlet;
036 3 Tons
102
8½ Tons
Supply air smoke detector
048 4 Tons
120
10 Tons
J
Non-powered convenience outlet;
060 5 Tons
150
12½ tons
Return & Supply air smoke detectors
072 6 Tons
180 & 181 15 Tons
K
Non-powered convenience outlet;
090 7½ Tons
240
20 Tons
Low-ambient kit; Supply air smoke detector
L
Non-powered convenience outlet;
Nominal Heating Capacity
Low-ambient kit
CPG
CPC/CPH (Factory-Installed Electric Heat)
Return & Supply air smoke detectors
045 45,000 BTU/h
XXX No Heat
M Powered convenience outlet;
090 90,000 BTU/h
010 10 kW
030 30 kW
Low-ambient kit
115 115,000 BTU/h
015 15 kW
031 30 kW
N
Powered convenience outlet;
140 140,000 BTU/h
016 15 kW
045 45 kW
Return air smoke detector
210 210,000 BTU/h
018 18 kW
046 45 kW
O
Powered convenience outlet;
350 350,000 BTU/h
020 20 kW
060 60 kW
Return & Supply air smoke detectors
400 400,000 BTU/h
025 25 kW
P
Powered convenience outlet;
See product specifications for heat size(s) available for each capacity.
Supply air smoke detector
Q
Powered convenience outlet; Low-
Voltage
ambient kit; Return air smoke detector
1
208-230/1/60
4 460/3/60
R
Powered convenience outlet; Low-
3
208-230/3/60
7 575/3/60
ambient kit; Supply air smoke detector
T
Powered convenience outlet;
Supply Fan/Drive Type/Motor
Low-ambient kit; Return & Supply
B
Belt Drive
V
2-Speed Belt Drive
air smoke detectors
D
Direct Drive
U
Non-powered convenience outlet;
Low-ambient kit; Return air smoke detector
Factory-Installed Options
V
Low-ambient kit; Return air smoke detector
X
No Options
W Low-ambient kit; Supply air smoke detector
A
Downflow Economizer
Y
Low-ambient kit; Return & Supply
H
Disconnect Switch (non-fused)
air smoke detectors
J
Downflow Economizer; Disconnect Switch (non-fused)
Z
Return & Supply air smoke detectors
Note: Not all options available for all products.
Factory-Installed Options
X
Standard Aluminized Heat Exchanger
S
Stainless-Steel Heat Exchanger
Factory-Installed Options
•
•
•
Economizers (Downflow): Based on air conditions, can provide outside air to cool the space.
•
Electric Heat Kits (CPC and CPH units only): Available in all voltage options.
•
Non-powered Convenience Outlet: A 120V, 15A, GFCI outlet makes it easier for technicians to service the unit once an electrician runs power to the outlet.
•
Powered Convenience Outlet: A 120V, 15A, GFCI outlet powered with a transformer built into the unit; for use when unit is not running.
When a factory-installed powered convenience outlet is installed in the equipment, the unit MCA (Min. Circuit Ampacity) will increase by 7.5A for 208/230V
units, increase by 3.75A for 460V units, and increase by 3A for 575V units. The MOP (Max. Overcurrent Protection) device must be sized accordingly.
•
•
Return Air and/or Supply Air Smoke Detectors: Return air and/or supply air smoke detectors are installed in the unit.
•
Two-speed Indoor Fan Blower Option: Available on 10-ton units. When the unit operates on the first stage of cooling, the fan operates at low speed to
provide 2/3 CFM airflow. When both stages of cooling operate, the blower delivers the total CFM airflow. In heating operation, the fan delivers the total CFM.
with the disconnect switch (non-fused) when it is ordered. Please note that for models with a powered convenience outlet option and a disconnect switch
(non-fused) option, the power to the powered convenience outlet will be shut off when the disconnect switch (non-fused) is in the off position.
ambient temperature to 35°F outside air temperature. On 7½- to 20-ton units, cooling operation is extended from 35°F ambient temperature
that for air conditioning (CPC units) and heat pump models (CPH units), the appropriate electric heat kit must be ordered to be factory-installed along
Stainless-Steel Heat Exchanger (CPG units only): A tubular heat exchanger made of 409-type stainless steel is installed in the unit.
Low-Ambient Kit: Allows for cooling operation at lower outdoor temperatures. On the 3- to 6-ton units, cooling operation is extended from 60°F
to 0°F outside air temperature.
Disconnect Switch (non-fused): A disconnect switch is installed in the unit and factory wiring will be complete from the switch to the unit. Please note