Gaggenau CM200610 User Manual
Page 32

32
Malfunction
Remedial action
Cause
Cleaning program
does not start.
System too hot.
Draw off some of the hot
water.
FILTER CHANGE
displayed.
Change filter.
Grinding unit is
making a loud noise.
Foreign objects in the
grinding unit (e.g. grit which
also occurs in superior types
of coffee).
Contact Customer Service.
Note: Ground coffee can still
be prepared.
Display ERROR 1
Appliance too cold.
Wait until the appliance has
warmed up to room
temperature.
Display ERROR 5
or ERROR 8
Technical malfunction.
Switch OFF the device at the
powerswitch 1 forat least
or ERROR 8
power switch 1 for at least
10 seconds.
If malfunctions cannot be eliminated, always call Customer Service!
Subject to alterations