beautypg.com

Pressure control – Graco Inc. 232633 User Manual

Page 14

background image

308870

14

Pressure Control

Control Board Diagnostics

1.

Fig. 15. Remove five screws (307) and
cover (322).

2.

Start sprayer.

3.

Turn ON/OFF switch ON.

4.

Observe LED operation and reference following
table:

LED
BLINKS

SPRAYER OPERATION

INDICATES

WHAT TO DO

Two times
repeatedly

Sprayer shuts down and LED contin-
ues to blink two times repeatedly

Run away pressure.
Pressure greater than
4500 psi (310 bar, 31
MPa).

1.

Check pressure transducer con-
nection at control board

2.

Replace pressure transducer

3.

Replace control board

Three
times re-
peatedly

Sprayer shuts down and LED contin-
ues to blink three times repeatedly

Pressure transducer is
faulty or missing

1.

Check pressure transducer con-
nection at control board

2.

Replace pressure transducer

3.

Replace control board

Four times
repeatedly

Sprayer shuts down and LED contin-
ues to blink four times repeatedly

Generator voltage is
low

1.

Increase engine throttle

2.

Check wiring connections

3.

Service Honda engine alternator

Five times
repeatedly

Sprayer shuts down and LED contin-
ues to blink five times repeatedly

High clutch current

1.

Check clutch 5-pin bulkhead con-
nector. Clean contacts.

2.

Measure 1.7

±

0.2

across clutch

field at 70

_

F

3.

Replace clutch field assembly

Six times
repeatedly

Sprayer shuts down and LED contin-
ues to blink six times repeatedly

High clutch temperature 1.

If clutch is new, let sprayer cool
down and then restart

2.

Inspect clutch. Replace clutch if
there is excessive wear.

3.

Remove pump pin, separate pin-
ion housing from clutch housing.
Rotate rotor clockwise to check
for excessive drag.