Test run, For model g0601 only – Grizzly G0442 User Manual
Page 32
-30-
Model g0442/g0601 (Mfg since 3/12)
test run
When the assembly is complete, test run the dust
collection system to make sure it operates prop-
erly.
if, during the test run, you cannot easily locate
the source of an unusual noise or vibration, stop
using the machine immediately, then review the
troubleshooting on page 47.
if you still cannot remedy a problem, contact our
tech support at (570) 546-9663 for assistance.
to test run the dust collection system:
1. Make sure you have read the safety instruc-
tions at the beginning of the manual and that
the machine is set up properly.
2. Make sure all tools and objects used during
setup are cleared away from the machine.
3. review the circuit requirements section
beginning on
page 11 and connect the
machine to the power source.
4. Flip the main power switch at the lower left
hand corner of the control box to the on ("l")
position to enable power to the switch.
5. press the on/oFF button to turn the machine
ON. Make sure your hand stays poised over
the switch in case you need to quickly turn
the machine
OFF.
6. Listen and watch for abnormal noises or
actions. the machine should run smoothly
with little or no vibration or rubbing noises.
— if you suspect any problems, immedi-
ately turn the machine
OFF, then discon-
nect the machine from power. refer to
troubleshooting on page 47 to identify
and fix any problems.
—if you cannot solve the problem with the
use of the
troubleshooting guide, contact
our tech support at (570) 546-9663 for
assistance.
7. press the tiMer button on the control box
and cycle through each of the times to make
sure the indicators light.
8. press the tiMer button on the remote con-
trol and cycle through the times in the same
manner as
step 7.
9. toggle the on/oFF button on both the con-
trol box and the remote control to make sure
they are working properly.
for model g0601 only
the Model g0601 uses a 3-phase motor. For
proper operation, the impeller inside the blow-
er housing must rotate counterclockwise when
viewed from above. since the motor and impeller
are directly connected, you must verify that the
motor rotates in the correct direction.
10. use a ladder to safely observe the motor fan
through the top motor cover as another per-
son turns the machine
ON and OFF.
— if the motor fan rotates counterclockwise
when viewed from above, the rotation
direction is correct.
— if the motor fan rotates clockwise when
viewed from above, the rotation direction
is incorrect and the motor is wired out-of-
phase. perform the
correcting phase
polarity procedure on page 14 to correctly
wire the machine to the power source so
that the motor and impeller spin counter-
clockwise when viewed from above.
if any part of your body contacts the spin-
ning impeller, severe cutting or amputation
injuries will occur. always keep yourself
and tools away from the impeller when the
machine is connected to power.