Model g0442/g0601 (Mfg since 3/12)

correcting phase polarity (g0601

only)

this subsection is only provided for troubleshoot-
ing. if you discover during the test run that the
machine will not operate, or that the impeller spins
backward, the power connections may be wired
out-of-phase. Without the proper test equipment
to determine the polarity of the power source legs,
wiring machinery to 3-phase power may require
trial-and-error. Correcting phase polarity is simply
a matter of reversing the positions where two of
the incoming power source wires are connected
inside the control box.

NOTICE

if this machine is wired out-of-phase, the

motor and impeller will spin in the wrong

direction. the efficiency of the dust col-

lector will be greatly reduced and will not

provide the rated cfm. you must make

sure the motor is spinning in the correct

direction before placing the machine into

full operation. perform Step 10 of the test

run on Page 30 to make sure the machine

is correctly wired.

to correct phase polarity:

1. disConneCt MAChine FroM poWer!

2. open the control box and swap the connec-

tions of any two incoming hot wires from the
power source (see

figure 4).

A1

Ground

2T1

6T3

14NO

4T2

1L1

5L3

13NO

3L2

NHD C-18D

2T1

4T2

6T3

98

97

A2

96

O

R

95

11

12

13

14

NHD NTH-14

A2

figure 4. Wire connections to swap to correct

phase polarity.

swap Any

two

of these

Wires

3. secure the control box cover, then re-connect

the machine to power.

4. perform step 10 of the test run on page 30

to confirm that the power connections are
correct.

— if the motor and impeller are still rotating

in the wrong direction, contact our tech
support at (570) 546-9663 for assistance.