User instructions, Oxygen depletion sensor, Flame failure device – Stovax PR0696 User Manual
Page 7: ‘running in, Servicing, Ventilation, Installation details
7
13
AR1171
7.14 Working from the outer edges, place the second
row of pebbles against the rear of the first row. Note the
orientation of each pebble, as this is important to the
performance of the fire. See diagram 14.
14
AR1172
7.15 Place the rear row of pebbles on top of the flame baffle,
these must touch the rear panel. See diagram 15.
15
AR1173
7.16 Place the remaining five pebbles between the second and
rear rows. See diagram 16.
16
AR1174
6
5
4
5
2
8. OXYGEN DEPlETION SENSOR
8.1 The appliance is fitted with an oxygen sensitive pilot system
which acts to cut off the gas supply to the fire should the
oxygen in the room fall below its normal level. If the fire is
turned off by this device, it usually indicates that there is a
problem with the flue system, and this should be inspected
by a qualified engineer. Do not attempt to use the fire
until an engineer says it is safe to do so.
This device is not a substitute for an independently
mounted carbon monoxide detector.
9. FlAME FAIlURE DEvICE
9.1 This is a safety feature incorporated in all GAZCO fires
which automatically switches off the gas supply if the pilot
light goes out and fails to heat the thermocouple.
10. ‘RUNNING IN’
10.1 The surface coating on the coals used in your GAZCO fire
will ‘burn off’ during the first few hours of use, producing a
harmless and temporary odour. This will disappear after a
short period of use. If the odour persists, ask your installer
for advice.
11. SERvICING
11.1 This fire must be serviced every 12 months by a qualified
Gas Engineer. In all correspondence, always quote the
appliance type and serial number, which may be found on
the data badge located on a chain beneath the control valve.
12. vENTIlATION
12.1 Any purpose provided ventilation should be checked
periodically to ensure that it is free from obstruction.
13. INSTAllATION DETAIlS
13.1 To assist in any future correspondence, your installer should
have completed this commissioning sheet, this records, the
essential installation details of the appliance. In all
correspondence always quote the Model Number and
Serial Number.
USER INSTRUCTIONS