Installation instructions, Installation / commissioning, Lighting the fire – Stovax PR0696 User Manual
Page 17: Commissioning
17
INSTAllATION INSTRUCTIONS
INSTAllATION / COMMISSIONING
11. lIGhTING ThE FIRE
11.1 Locate the control valve on the appliance. There are two
control knobs on the valve, the right hand knob controls
the pilot ignition and the left hand knob controls the main
burner.
11.2 If your appliance has already been upgraded to battery
remote control, please refer to the instructions provided
with the upgrade to operate the remote control. The
following instructions will work for either situation.
1
AR0914
11.3 Ensure that the left-hand control knob is pointing to off ( ).
11.4 Ensure that the right hand control knob is pointing to off ( ).
11.5 Press in the right hand control knob and rotate it anti-
clockwise until a click is heard (keep pressing in) and the
knob is pointing to pilot ( ). The pilot should now light.
If the pilot has not lit, repeat the procedure until it does.
11.6 Keep the control knob pressed for 10 seconds and then
release it, the pilot should stay alight. If the pilot goes out,
repeat the procedures until it does.
11.7 If the pilot will not light after repeated attempts, contact the
retailer or installer from whom the appliance was purchased.
11.8 Turn the right hand control to point to main burner (
).
The
appliance can now be controlled using the left hand control
knob.
11.9 Turn the left hand control knob to point to low fire (
),
the main burner will light on low. The burner can now be
controlled between low and high settings. Turn the control
knob anti-clockwise increase the flame height and clockwise
to decrease the flame height.
ThE YEllOW FlAMES WIll APPEAR WhEN ThE FIRE hAS
GAINED SUFFICIENT hEAT - TYPICAllY 10 TO 20 MINUTES.
1. COMMISSIONING
1.1 Close all windows and doors to the room, check all controls,
and allow fire to burn on maximum for 5 minutes. Test for
spillage of flue products using a smoke match. Pass the
lighted smoke match along the top front edge just inside the
opening or canopy. See diagram 1.
1
AR0726
Hotbox
Convector
1.2 If the fire spills, run for a further 10 minutes and re-check. If
the flue restrictor plate has been fitted to the fire this can be
removed to assist flue flow if required. ( Convector only)
1.3 If there are extractor fans in the room or adjacent rooms, the
spillage test must be repeated with the extractors running on
maximum.
IF SPIllAGE PERSISTS, DISCONNECT ThE APPlIANCE
AND SEEk EXPERT ADvICE.
For future reference record the installation details on the
commissioning sheet on page 3 of these instructions.