SYMPTOM

Low operating pressure

Low permeate flow rate

POSSIBLE CAUSES

Insufficient feed water pressure

or flow

Clogged pre-filter cartridge

High flow rates

Dirty or fouled membrane

elements

Solenoid valve not opening

Pump rotating backwards

(three-phase power only)

Insufficient electrical power

Pump not operating correctly

Low operating pressure

REMEDIES

Open the feed pressure, open the

feed water valve, check for

restrictions.

Replace the pre-filter cartridge.

Close the concentrate valve,

check the permeate and concen-

trate flow rates and adjust if nec-
essary. Excessive permeate flow

may indicate a damaged O-ring.

Flush and clean the membrane

elements.

Clean or replace the solenoid

valve.

Switch any two of the three-

phase leads to the motor starter.

Check the fuses or circuit break-

er, measure the voltage.

See the pump instructions.

See the possible causes for low

pressure.