symptom

possible Cause

possible solution

Machine does not
start or a breaker
trips.

1. plug or receptacle is at fault or wired

incorrectly.

2. start capacitor is faulty.

3. Motor connection is wired incorrectly.
4. power supply is faulty, or is switched oFF.

5. Centrifugal switch is at fault.
6. Motor on button or on/oFF switch is

faulty.

7. Motor is at fault.

1. test power plug and receptacle for good contact and

correct wiring.

2. test and replace capacitor as required (see photo,

Page 44).

3. Correct motor wiring (see

Page 45).

4. Make sure all hot lines and grounds are operational

and have correct voltage on all legs.

5. adjust or replace the centrifugal switch.
6. replace faulty on button or on/oFF switch (see

photo,

Page 44).

7. test, repair or replace motor.

Machine has
vibration or noisy
operation.

1. Motor or component is loose.

2. Motor fan is rubbing on fan cover.

3. v-belt(s) is worn or is loose.

4. pulley is loose.

5. Motor bearings are at fault.

6. Centrifugal switch.

1. inspect, replace for stripped or damaged bolts/nuts,

and re-tighten with thread locking fluid.

2. replace dented fan cover, and replace loose or

damaged fan.

3. inspect belt(s), replace as matched sets, and

re-tension.

4. remove pulley, replace shaft, pulley, setscrew, and

key as required, and realign.

5. Check bearings, replace motor or bearings as

required.

6. normal snap/click sound on rpM wind down. no

problem exists.

Motor overheats.

1. Motor overloaded.
2. air circulation through the motor restricted.

1. reduce load on motor.
2. Clean off motor to provide normal air circulation.

Motor & Electrical

troubleshooting

Review the troubleshooting and procedures in this section if a problem develops with your machine. If you
need replacement parts or additional help with a procedure, call our Technical Support at (570) 546-9663.

Note: Please gather the serial number and manufacture date of your machine before calling.