Knife setting gauge, Dust collection – Grizzly G0633/G0634 User Manual
Page 21
G0633/G0634 Jointer/Planer Combo Machine
-19-
Figure 14. Knife setting gauge assembly.
Assemble the knife setting gauge using the knife
setting gauge rod, feet and 9mm e-clips as shown
in
Figure 14.
Knife Setting Gauge
Figure 15. Dust hose attached to jointer dust
port.
Dust Collection
DO NOT operate the Model G0633/G0634
without an adequate dust collection system.
This machine creates substantial amounts
of wood dust while operating. Failure to use
a dust collection system can result in short
and long-term respiratory illness.
Recommended CFM at Each Dust Port: 400
Do not confuse this CFM recommendation with
the rating of the dust collector. To determine
the CFM at the dust port, you must consider
these variables: (1) CFM rating of the dust col-
lector, (2) hose type and length between the
dust collector and the machine, (3) number
of branches or wyes, and (4) amount of other
open lines throughout the system. Explaining
how to calculate these variables is beyond the
scope of this manual. Consult an expert or pur-
chase a good dust collection "how-to" book.
To connect a dust collection hose:
1. Fit the 4" dust hose over the jointer dust
port, (see
Figure 15), or over the planer dust
port (see
Figure 16), depending upon which
operation mode is setup, and secure in place
with a hose clamp.
2. Tug the hose to make sure it does not come
off.
Note: A tight fit is necessary for proper per-
formance.
Figure 16. Dust hose attached to planer dust
port.