41

Touchpad/Voice Feedback

After Pressing

*

Key

Trouble Condition

AC POWER FAILURE

The panel power transformer may be unplugged or there may be an AC power outage. If

the transformer is plugged in, check the circuit breaker or fuse that controls that outlet.

The backup battery will take over, but if AC power is not restored within 15 minutes, the

system will alert you and the central monitoring station (if your system is monitored). It

reports again when power is restored.

LOW BATT

The emergency backup battery in the control panel is low and must be recharged or

replaced. If AC power is out, the security system may shut down once the battery is below

the operating level. When AC power is restored, the panel recharges the battery. If the

trouble condition exists more than 24 hours after AC power is restored, call your security

dealer for service.

SENSOR SUPERVISORY

There is a problem with how the sensor is communicating with the panel.

1.

Test the sensor in Test Mode.

2.

If testing the sensor does not clear the trouble condition, call your security dealer for

service.

SENSOR TROUBLE

A sensor may have an internal problem or a fire/smoke sensor may not have properly reset

after activation, or the sensing chamber may be dirty or partially obstructed.

1.

Test the sensor in Test Mode.

2.

If testing the sensor does not clear the trouble condition, call your security dealer for

service.

SENSOR XX LOW BATTERY A sensor has a low battery.

1.

Disarm the system.

2.

Remove the sensor cover. If the battery is an Alkaline AA or AAA, change the battery.

If the battery is any other type, call your security dealer for service.

SENSOR XX TAMPER

A sensor cover is off or open. Secure the cover and trip the sensor to clear the tamper

condition.

PHONE FAILURE TROUBLE The system can’t communicate with the central monitoring station. The system tries to

report to the central station three times before indicating Phone Failure Trouble, then

makes five more reporting attempts.

1.

Make sure the panel is connected to the special phone jack installed by your security

dealer.

2.

Disconnect the panel from the special phone jack and check phones for dial tone. If

you hear a dial tone, call your security dealer for service. If you don’t hear a dial tone

from any phones, telephone service in your area may be out.

Phone Failure Trouble takes precedence over other system problems, so you must clear

the Phone Failure message (by disarming the panel) before you’re able to see other sys-

tem messages.

RECEIVER INTERFERENCE

or RECEIVER FAILURE

There is a receiver failure or receiver interference problem. Call your security dealer for

service.

MEMORY FAILURE or all text

is lit on a fixed display touch-

pad

There is a system memory failure. Call your security dealer for service.

AUXILIARY PHONE TROU-

BLE X

There is a problem with the cellular backup reporting portion of your system. Call your

security dealer for service.

AUX POWER FAIL

There is a problem with the power supplied to parts of the system. Call your security dealer

for service.

BUS FAILURE UNIT NN

There is a problem with one of the peripheral devices in your system. Call your security

dealer for service.