beautypg.com

Caution – GE C2S980 User Manual

Page 45

background image

45

Read these instructions completely and carefully.

Connect the Range to the Gas Supply

Because hard piping restricts movement of the
range, the use of a CSA International-certified
flexible metal appliance connector is recommended
unless local codes require a hard-piped connection.
Never use an old connector when installing a
new range. If the hard piping method is used, you
must carefully align the pipe; the range cannot be
moved after the connection is made.
To prevent gas leaks, put pipe joint compound on,
or wrap pipe thread tape with Teflon* around, all
male (external) pipe threads.

Install a manual gas line shut-off valve in the
gas line in an easily accessed location outside
of the range. Make sure everyone operating
the range knows where and how to shut off
the gas supply to the range.
Install male 1/2

″ flare union adapter to

the 1/2

″ NPT internal thread elbow at inlet

of regulator. Use a backup wrench on the
regulator fitting to avoid damage.
When installing the range from the front,
remove the 90° elbow for easier installation.
Install male 1/2

″ or 3/4″ flare union adapter to

the NPT internal thread of the manual shut-off

valve, taking care to backup the shut-off valve
to keep it from turning.
Connect flexible metal appliance connector
to the adapter on the range. Position range
to permit connection at the shut-off valve.
When all connections have been made, make
sure all range controls are in the off position
and turn on the main gas supply valve.
Use a liquid leak detector at all joints and
connections to check for leaks in the system.

When using test pressures greater than 1/2 psig
to pressure test the gas supply system of the
residence, disconnect the range and individual
shut-off valve from the gas supply piping. When
using test pressures of 1/2 psig or less to test the
gas supply system, simply isolate the range from
the gas supply system by closing the individual
shut-off valve.
*Teflon: Registered trademark of DuPont

CAUTION :

DO NOT USE A

FLAME TO CHECK FOR GAS LEAKS.

Shut off the main gas supply valve before disconnecting the old range and leave it off
until the new hookup has been completed. Don’t forget to relight the pilot on other gas
appliances when you turn the gas back on.

Flexible Connector Hookup

Rigid Pipe Hookup Options

Pressure
regulator

Gas Flow into Range

Flex
connector
(6 ft. max.)

Adapter

Installer: Inform
the consumer of
the location of the
gas shut-off valve.

1/2

″ or 3/4″

Gas pipe

Adapter

Gas
shut-off
valve

Pressure
regulator

45° Elbow

Nipple

Union

90° Elbow

Black
iron pipe

Union

Nipple

Gas

shut-off

valve

1/2

″ or 3/4″

Gas pipe

Gas Flow into Range

Installer: Inform the consumer of the
location of the gas shut-off valve.

Gas Flow into Range

Gas
shut-off
valve

1/2

″ or 3/4″

Gas pipe

Pressure
regulator

Nipple

90° Elbow

90° Elbow

Adapter

Adapter

90° Elbow

Quick connect
or union

Installer: Inform the consumer of the
location of the gas shut-off valve.

Alternate Hookup

Nipple

Nipple

90°
Elbow

Consumer

S

uppor

t

Operating

Instructions

Safety

Instructions

Installation

Instructions

Tr

oubleshooting

Tips