beautypg.com

GE JKP75SP User Manual

Jkp75sp, 27" built-in convection/thermal wall oven

background image

JKP75SP

GE

®

27" Built-In Convection/Thermal Wall Oven

For answers to your Monogram,

®

GE Profile

or

GE

®

appliance questions, visit our website at

ge.com or call GE Answer Center

®

service,

800.626.2000.

Listed by

Underwriters

Laboratories

320363

Specification Created 5/09

KW Rating

240V

6.8

208V

5.1

Breaker Size

240V

30 Amps

208V

30 Amps

Dimensions and Installation Information (in inches)

Note: Cabinets installed adjacent to wall ovens

must have an adhesion spec of at least a 194°F

temperature rating.
Note: If marks, blemishes or the cutout opening is

visible above the installed oven, it may be necessary to

add wood shims under the runners and front trim until

the marks or openings are covered.
Note: Door handle protrudes 3" from door face.

Cabinets and drawers on adjacent 45° and 90°

walls should be placed to avoid interference with

the handle.

Electric wall ovens are not approved for installation

with a plug and receptacle. They must be hard wired

in accordance with installation instructions.

Cabinet

27"

A – Cabinet width required

27" min.

B – Minimum cabinet depth

23-5/8"

C – Opening width

25" min. - 25-1/4" max

D – Opening height

50-1/8" max

E – Recommended minimum cutout location from floor

13-1/4"

Oven
F – Overall depth*

23-5/8"

G – Overall height with trim

51-7/8" - 52-3/4"

Overall height without trim

51"

H – Overall width

26-5/8"

*Depth including door handle is approximately 26-7/10" min. to 26-8/10" max.

CL

Suitable

bracing

to support

runners

18"

Over centerline

of cabinet

(must support 300 lbs.)

2" x 4" or

equivalent

runners

10

Locate

junction box

for 27"models

either 5" MIN.

below cutout

floor or 44"

MIN. above

cutout floor

Access

from

adjacent

cabinet

required

Allow 3/4"

for overlap

over all edges

of cutout

A

Minimum

cutout location

from floor

D

E

2" X 4" or

equiv. runners

(cutout floor)

21" MIN.

door opening

allowance

B

C

H

F

G

Locate

junction box

for 24"models

56" MIN. above

cutout floor

Conduit

(48-1/2" Long)

21

Cabinet

27"

A – Cabinet width required

27" min.

B – Minimum cabinet depth

23-5/8"

C – Opening width

25" min. - 25-1/4" max

D – Opening height

50-1/8" max

E – Recommended minimum cutout location from floor

13-1/4"

Oven
F – Overall depth*

23-5/8"

G – Overall height with trim

51-7/8" - 52-3/4"

Overall height without trim

51"

H – Overall width

26-5/8"

*Depth including door handle is approximately 26-7/10" min. to 26-8/10" max.

CL

Suitable

bracing

to support

runners

18"

Over centerline

of cabinet

(must support 300 lbs.)

2" x 4" or

equivalent

runners

10

Locate

junction box

for 27"models

either 5" MIN.

below cutout

floor or 44"

MIN. above

cutout floor

Access

from

adjacent

cabinet

required

Allow 3/4"

for overlap

over all edges

of cutout

A

Minimum

cutout location

from floor

D

E

2" X 4" or

equiv. runners

(cutout floor)

21" MIN.

door opening

allowance

B

C

H

F

G

Locate

junction box

for 24"models

56" MIN. above

cutout floor

Conduit

(48-1/2" Long)

21