Galaxy 65 Troubleshooting

63

7.4.1 System Faults

7.4.2 Power Supply/Cooling Faults

Symptom

Cause

Action

1 The SYSTEM LED will

illuminate AMBER on
the LRC

2 Audible Alarm sound

The ESI processor
has detected an
internal fault (e.g.
failure of an
internal
communications
path)

1 Check for other AMBER LED indications on the

Power Supply/Cooling modules. If there is a
PSU error present there may be a
communications problem with that Power
Supply/Cooling module. Remove and then re-fit
the module, if the problem persists then change
the module.

2 Check for other AMBER LED indications on the

drives carriers. If none are evident then there
may either be an ESI processor problem or a
Backplane problem.

3 Change the Ops Panel module (see

7.12.2

).

Symptom

Cause

Action

1 Ops Panel

FAULTLED AMBER

2 An AMBER LED on

one or more Power
Supply/Cooling
Modules.

3 Audible Alarm

Sounding.

1 Any power

fault.

2 A fan failure.

3 A thermal

condition
which could
cause PSU
overheating.

1 Check Power On/Off Switch on rear of Power

Supply/Cooling module is switched ON.(not
accessible on later models)

2 Check AC Mains Connections to Power Supply/

Cooling module is live.

3 Disconnect the Power Supply/Cooling module

from mains power and remove the module from
the system, Re-install: if problem persists,
replace Power Supply/Cooling Module.

4 Reduce the ambient temperature.