beautypg.com

Setting method 1: by gyrocompass specifications – Furuno FR-2135S User Manual

Page 48

background image

4-4

Setting method 1: by gyrocompass specifications

1) Gyrocompass type

2) Frequency

Gyrocompass
type

SW

1-4

SW

1-5

SW

1-6

JP1

Frequency

SW

1-7

SW

1-8

Remarks

AC synchronous

OFF

OFF

OFF #1,

#2, #3

50/60Hz

OFF

OFF

AC synchronous
pulsating current

DC synchronous

OFF

OFF

OFF #2,

#3, #4

400Hz

ON

OFF

AC synchronous
pulsating current

DC step

ON

OFF

OFF #4,

#5, #6

500Hz

OFF

ON

AC synchronous
pulsating current

Full-wave
pulsating current

OFF

ON

OFF #4,

#5, #6

DC

ON

ON

DC synchronous
DC step

Half-wave
pulsating current

ON

ON

OFF #4,

#5, #6

3) Rotor voltage
(between R1 & R2)

4) Stator voltage
(between S1 and S2)

Rotor voltage

SW 2-1

JP3

Stator voltage

SW 2-2

SW 2-3

JP2

20 V to 45 VAC

ON

#2

20 V to 45 VAC, or
20 V to 60 VDC

ON

OFF

#2

30 V to 70 VAC

OFF

#2

40 V to 90 VAC

ON

#1

20 V to 45 VAC, or
20 V to 60 VDC

OFF

OFF

#2

60 V to 135 VAC

OFF

#1

40 V to 90 VAC

ON

OFF

#1

60 V to 135 VAC

OFF

OFF

#1

5) Ratio

6) Supply voltage

Ratio

SW1-1

SW 1-2

SW1-3

Supply voltage

JP4

JP5

360x

OFF

OFF

OFF

20 V to 45 VAC, or
20 V to 60 VDC

#2

#2

180x

ON

OFF

OFF

90X

OFF

ON

OFF

30 V to 135 VAC, or
40 V to 100 VDC

#1

#1

36X

ON

ON

OFF

7) AD-10 format data
Tx interval

9) NMEA-0183
Version no.

8) NMEA-0183
Tx interval and Output sentence

Select data transmitting interval for ports 1 to 6 by jumper wires
JP6 and JP7.

Tx
interval

SW
2-5

Note: The Tx interval is available in 25 ms or 200 ms.

25 ms is for radar; 200 ms is for all other equipment.

1 s

ON

ON

200 ms

OFF

100 ms

OFF

SW
2-6

ON

ON

OFF

OFF

Output
sentence

HDT

HDT

HDT

HDT+VHW

25 ms

Version no.

OFF

1.5

SW3-1

2.0

ON

10) NMEA-0183
Baud rate

Baud rate

OFF

4860bps

SW3-2

38400bps

ON

11) NMEA-0183
Talker

Talker

OFF

AG

SW3-3

HE

ON