beautypg.com

FUJITSU MHW2060AC User Manual

Page 200

background image

Interface

(48) READ VERIFY SECTOR(S) EXT (X’42): Option (customizing)

Description

This command is the extended command of the READ VERIFY SECTOR(S)
command. The LBA specification is increased from 28 bits to 48 bits, and the
maximum number of sectors that can be transferred by a single command is
changed from 100h to 10000h. Other command controls are the same as those of
the READ VERIFY SECTOR(S) command.

At command issuance (I/O registers setting contents)

1F7

h

(CM) 0 1 0 0 0 0 1 0

1F6

h

(DH) 1 L 1

DV

xx

1F5

h

(CH) P

1F5

h

(CH) C

1F4

h

(CL) P

1F4

h

(CL) C

1F3

h

(SN) P

1F3

h

(SN) C

1F2

1F1

LBA (23-16)

xx

h

(SC) P

1F2

h

(SC) C

h

(FR) P

1F1

h

(FR) C

LBA (47-40)

LBA (39-32)
LBA (15-8)
LBA (31-24)
LBA (7-0)
Sector count (15-8)
Sector count (7-0)
xx

C: Current
P: Previous

At command completion (I/O registers contents to be read)

1F7

h

(ST) Status

information

1F6

h

(DH) 1 L 1

DV

xx

1F5

h

(CH) 1

1F5

h

(CH) 0

1F4

h

(CL) 1

1F4

h

(CL) 0

1F3

h

(SN) 1

1F3

1F1

h

(ER)

h

(SN) 0

1F2

h

(SC) 1

1F2

h

(SC) 0

LBA (47-40)
LBA (23-16)
LBA (39-32)
LBA (15-8)
LBA (31-24)
LBA (7-0)
xx
xx
Error information

0: HOB=0
1: HOB=1

5-124

C141-E258