beautypg.com

FUJITSU MHW2060AC User Manual

Page 101

background image

5.3 Host Commands

(4) WRITE VERIFY (X’3C’)

This command operates similarly to the WRITE SECTOR(S) command except
that the device verifies each sector immediately after being written. The verify
operation is a read and check for data errors without data transfer. Any error that
is detected during the verify operation is posted.

After all sectors are verified, the last interruption (INTRQ for command
termination) is generated.

At command issuance (I/O registers setting contents)

1F7

H

(CM) 0 0 1 1 1 1 0 0

1F6

H

(DH)

x

L

x

DV Start head No. / LBA

[MSB]

1F5

H

(CH)

1F4

H

(CL)

1F3

H

(SN)

1F2

H

(SC)

1F1

H

(FR)

Start cylinder No. [MSB] / LBA

Start cylinder No. [LSB] / LBA

Start sector No. / LBA [LSB]

Transfer sector count

xx


At command completion (I/O registers contents to be read)

1F7

H

(ST) Status

information

1F6

H

(DH)

x

L

x

DV End head No. / LBA [MSB]

1F5

H

(CH)

1F4

H

(CL)

1F3

H

(SN)

1F2

H

(SC)

1F1

H

(ER)

End cylinder No. [MSB] / LBA

End cylinder No. [LSB] / LBA

End sector No. / LBA [LSB]

00 (*1)

Error information

*1

If the command is terminated due to an error, the remaining number of
sectors of which data was not transferred is set in this register.

C141-E258

5-25

This manual is related to the following products: