Frymaster 45 Series User Manual
Page 55

2-7
ITEM
PART #
COMPONENT
1
806-0225SP
Deflector (Target) Assembly (use 814-0034 for ceramic only)
2
826-1155
Ignitor Kit, Optional Piezo
807-1906
Electrode Assembly
810-1001
Trigger
3
823-0496
Manifold, Burner
4
Orifice
810-0407
Manufactured Gas, 2.15mm (0-1999 Ft)
Natural Gas
826-1357
1.45mm (0-1999 Ft) (Pkg of 10)
826-1386
1.40mm (2000-3999 Ft) (Pkg of 10)
810-0361
1.36mm (4000-5999 Ft)
810-0131
1.30mm (6000-7999 Ft)
812-1301
1.27mm (8000-8999 Ft)
810-0343
1.25mm (9000-10,000 Ft)
Propane/Butane Gas
826-1387
0.86mm (0-1999 Ft) (Pkg of 10)
810-0952
0.82mm (2000-3999 Ft)
810-0339
0.81mm (4000-5999 Ft)
812-0914
0.78mm (6000-7999 Ft)
812-1302
0.76mm (8000-8999 Ft)
812-0444
0.74mm (9000-10,000 Ft)
5
Pilot Assembly
810-1830
Natural Gas, w/Thermopile (non-CE w/twin-leads)
806-8688SP
Natural Gas, w/Thermocouple (CE w/co-axial lead)
810-0426
Natural Gas, w/o Thermopile or Thermocouple
810-0616
Propane or Butane Gas, w/Thermopile (non-CE w/co-axial lead)
810-1773
Propane or Butane Gas, w/Thermopile (non-CE w/twin leads)
806-8689SP
Propane or Butane Gas, w/Thermocouple (CE)
810-0427
Propane or Butane Gas, w/o Thermopile or Thermocouple)
810-0683
Manufactured Gas, w/Thermocouple (CE and non-CE)
6
823-0574
Shield Assembly, Burner Heat
7
Thermopile/Thermocouple
810-1873
Thermopile w/push-on terminals (used in non-CE Pilot Assemblies)
826-1527
Kit, Thermocouple with adapter (used in CE Pilot Assemblies)
812-1284
Thermocouple w/threaded terminal (component of 826-1527)
8
Tube, Pilot Gas
810-0705
For use with all burner assemblies except Hong Kong export units
812-0278
For use with Hong Kong export units only
9
810-0691
Tube, Vent
10
Valve, Gas (Non-CE) (see Note 1 below)
*
810-0975
Knob, Gas Valve
807-3294
Natural Gas (for 240V, use 807-0025)
807-3295
Propane/Butane Gas (for 240V, use 807-0759)
807-3354
Manufactured Gas (other than Hong Kong export units)
810-0353
Manufactured Gas (Hong Kong export units only)
11
Valve, Gas (CE)
806-6710SP
Natural Gas (see Note 2 below)
806-6711SP
Propane Gas (see Note 2 below)
* Not illustrated.
NOTES: 1. A gas valve capacitor (P/N 806-4781) is required on gas valves used on units with
Thermostat Controllers. 2. An adapter kit (P/N 812-1256SP) is required to connect the high-limit
thermostat to Item 11. See Page 2-34 for details.