Specifications, Electrical, Plumbing – Follett 400 Series User Manual
Page 4
Specifications
4
Electrical
Model
number
Full
load
amps
Max.
fuse
size
MC400
series
icemaker
115/60/1 11.0
amps
20
amps
Ambient specifications
Air temperature
100˚F/38˚C max.
50˚F/10˚C min. (best performance below 80˚F/27˚C)
Water temperature
90˚F/32˚C max.
40˚F/4˚C min. (best performance below 70˚F/21˚C)
Water pressure
70 P.S.I. max.(482kPA) 10 P.S.I min. (89kPA)
Plumbing
Your new icemaker is equipped with a drain line to simplify draining the evaporator and float reservoir. The tube
labeled “float/evap drain” is for SERVICE USE ONLY and must NOT be connected to the icemaker drain.
Water line sizes
Make up water (inlet to float)
1/4" min.
Condenser
(water-cooled
only)
3/8"
min.
Drain
line
sizes
Icemaker
drain
3/4"
min.
Condenser
(water-cooled
only)
3/8"
min.
Slope to drain
1/4" per foot (6mm per 30.4cm run)
1/2" min.
•
Water shut-off recommended within 10 feet (3m), drain to be hard-piped and insulated
•
Separate drains for icemaker and condenser. To prevent back flow, do NOT connect drains.
•
Follett recommends installation of a Follett water filter system (part# 00130229) in icemaker inlet water line
Field Wiring: countertop dispensers with Satellite-fill icemakers
Consult enclosed D400A/W, R400A/W, MCD400A/W manual.