23. Connect the ice transport tube(s) to the dispenser:

a)

Drill 3/16" (5mm) holes through both sides of the tube

1/2" (13mm) from the tube end.

b)

Collapse tube and insert through gasketed hole (Fig. 14.1).

c) Match tube holes to bracket tabs.

24. Route bin thermostat capillary tube from the 4" x 4"

(102mm x 102mm) junction box into bin alongside the ice
transport tube. Secure capillary tube into bracket (Fig. 8).

25. Reinstall the dispenser cover with supplied screws (Fig. 14).

26. Install telescoping chase.

a)

Mount lower chase section to chase bracket on counter

with supplied screws (Fig. 15.1).

b) Position upper chase section over lower chase section.

Align top of upper section to top of stainless dispenser top
and secure with screw (Fig. 15.2).

c) Drill pilot holes on both sides of chase and secure with

supplied screws (Fig. 15.3).

27. Turn icemaker power and water on.

28. After icemaker has made ice for approximately 15 minutes

complete the following start-up checks:

a)

Dispense

ice.

b)

Hold ice on bin thermostat and make sure

icemaker

shuts

off.

c) Remove ice from bin thermostat and make sure

icemaker

restarts.

Note: Icemaker has a 20 minute restart delay.