Follett 400 Series User Manual
Page 11
Satellite-fill icemaker installation
18. Ice transport tube chase may be located
behind or to either side of the dispenser
(Fig. 10 and 11). Using the chase
mounting bracket (Fig. 12) as a template
mark the counter for the ice transport
tube(s) in one of the locations shown in
Fig. 10 and 11. Within the template outline
drill one 2.25" (58mm) to 2.375" (61mm)
hole for each ice transport tube. Secure
the chase mounting bracket to the counter
using supplied screws (Fig. 12).
Fig. 10 – Single ice tube dispensers
Fig. 11 – Double ice tube dispensers
11
2.25" (57mm) -
2.375" (61mm)
dia. hole
typical
1.25
(32mm)
1.25" (32mm)
1.25"
(32mm)
1.50" (3
8
mm)
1.50" (3
8
mm)
front
side entr
y
chase
side entr
y
chase
rear entry chase
4.50" (115mm)
4.50" (115mm)
A
B
6"
(153mm)
2.25" (57mm) -
2.375" (61mm)
dia. hole
typical
1.25
(32mm)
1.25" (32mm)
1.25"
(32mm)
3" (77mm)
3" (77mm)
front
side entr
y
chase
side entr
y
chase
rear entry chase
A
B
6"
(153mm)
Fig. 12
Dimension A
Dimension B
Single tube – Fig. 10
22" (559mm) dispenser
11.00" (280mm)
8.00" (242mm)
24" (607mm) dispenser
12.00" (312mm)
9.00" (299mm)
30" (762mm) dispenser
15.00" (762mm) 12.00" (343mm)
Double tube – Fig. 11
22" (559mm) dispenser
9.50" (242mm)
8.00" (204mm)
24" (607mm) dispenser
10.50" (273mm)
9.00" (242mm)
30" (762mm) dispenser
13.50" (343mm) 12.00" (305mm)
44" (1118mm) dispenser 20.50" (521mm) 19.00" (483mm)