beautypg.com

Non-ce standard for incoming gas pressures – Frymaster FOOTPRINT 8195991 User Manual

Page 7

background image

1-2

1.3 Safety

Information

Before attempting to operate your unit, read the instructions in this manual thoroughly. Throughout
this manual, you will find notations enclosed in double-bordered boxes similar to the ones that
follow.

CAUTION

CAUTION

boxes contain information about actions or conditions that may cause or result

in a malfunction of your system

.

WARNING

WARNING

boxes contain information about actions or conditions that may cause or result

in damage to your system

, and which may cause your system to malfunction.

DANGER

DANGER

boxes contain information about actions or conditions that may cause or result

in injury to personnel

, and which may cause damage to your system and/or cause your

system to malfunction.


Your fryer is equipped with automatic safety features:

1. High temperature detection shuts off gas to the burner assembly should the controlling

thermostat fail.


2. An optional safety switch built into the drain valve prevents burner ignition with the drain valve

even partially open.

1.4

European Community (CE) Specific Information

The European Community (CE) has established certain specific standards regarding equipment of
this type. Whenever a conflict exists between CE and non-CE standards, the information or
instructions concerned are identified by means of shadowed boxes similar to the one below.

Non-CE Standard

for Incoming Gas Pressures

Type

Minimum

Maximum

6" W.C.

14" W.C.

Natural

1.49 kPa

3.49 kPa

14.68 mbar 34.72 mbar

11" W.C.

14" W.C.

LP

2.74 kPa

3.49 kPa

27.28 mbar 34.84 mbar