beautypg.com

Frymaster FOOTPRINT 8195991 User Manual

Page 44

background image

6-3

PROBLEM

PROBABLE CAUSES

CORRECTIVE ACTION

A. Failed computer/controller.

A. If available, substitute a

computer/controller known to be
working for the suspect
computer/controller. If the fryer
functions correctly, order
replacement from FASC.

Display shows

,

heating indicator

cycles on and off

normally, but

burners will not

light and blower is

not running.

B. Damaged computer/controller

wiring harness.

B. If available, substitute a harness

known to be good for the suspect
harness. If the fryer functions
correctly, order replacement
harness from FASC.

Fryer is slow coming

out of melt cycle.

Display shows

a short time

after coming out of

melt cycle.

Dirty or obstructed combustion air
blower.

Clean and adjust per instructions

in Chapter 5 of this manual.

Fryer is operating

normally, but

recovery is slow

when cooking.

Dirty or obstructed combustion air
blower.

Clean and adjust per instructions

in Chapter 5 of this manual.

A. Dirty or obstructed combustion air

blower.

A. Clean and adjust per instructions

in Chapter 5 of this manual.

B. Dirty or obstructed gas valve vent

tube (non-CE fryers only).

B. Clean per instructions in Chapter

5 of this manual.

Fryer is operating

normally, but

produces a popping

sound when burners

ignite. C. Malfunctioning combustion air

blower.

C. If blower is slow to come up to

speed, contact FASC for service.

Display shows

and alarm

sounds, but fryer

operates normally

(false alarm).

Failed computer/controller.

If available, substitute a

computer/controller known to be
working for the suspect
computer/controller. If the fryer
functions correctly, order
replacement from FASC.

Computer will not

go into program

mode or some

buttons do not

actuate.

Failed computer/controller.

If available, substitute a
computer/controller known to be
working for the suspect
computer/controller. If the fryer
functions correctly, order
replacement from FASC.

Heat indicator is on

and blower is

running, but burner

will not ignite.

Blown fuse on interface board or
ignition module.

Replace

fuse.