beautypg.com

Frymaster FOOTPRINT 8195991 User Manual

Page 38

background image


5-5

4. Remove the plastic wrap from the blower motor assembly. Reassemble the blower motor

assembly and blower housing. Reinstall the blower assembly in the fryer.


5. Reinstall the blower shield or shield assembly.

6. Light the fryer in accordance with the procedure described in Chapter 3, Section 3.1.

7. After the burners have been lit for at least 90 seconds, observe the flames through the burner

viewing ports located on each side of the combustion air blower.

The air/gas mixture is properly adjusted when the burner manifold pressure is in accordance with the
applicable table on page 2-7 and the burners display a bright orange-red glow. If a blue flame is
observed, or if there are dark spots on a burner face, the air/gas mixture requires adjustment.

On the side of the blower housing opposite the motor is a plate with one or two locking nuts.
Loosen the nut(s) enough to allow the plate to be moved, then adjust the position of the plate to open
or close the air intake opening until a bright orange-red glow is obtained. Carefully hold the plate in
position and tighten the locking nut(s).

TYPICAL BLOWER ASSEMBLY

SOME CE BLOWER ASSEMBLIES
MAY BE CONFIGURED THIS WAY

Right

Viewing

Port

Left Viewing

Port is Behind

Motor

(NOTE: Blower

shield omitted

for clarity.)