beautypg.com

Frymaster FOOTPRINT 8195991 User Manual

Page 37

background image


5-4

QUARTERLY CHECKS AND SERVICE

Clean Combustion Air Blower Assembly

1. Disconnect the blower wiring harness and remove the four blower mounting nuts.

2. Remove the three fasteners that secure the blower motor assembly to the blower housing, and

separate the two components.

Remove these fasteners.

3. Wrap the motor with plastic wrap to prevent water from entering it. Spray degreaser or

detergent on the blower wheel and the blower housing. Allow it to soak for five minutes. Rinse
the wheel and housing with hot tap water, then dry with a clean cloth.

Blower Housing

Blower Wheel

Wrap the motor and wires

with plastic wrap or a

plastic bag.

Wiring connection

Blower

assembly

mounting nuts