beautypg.com

H per kw, Ce standard, Gas connection pipe sizes – Frymaster FOOTPRINT 8195991 User Manual

Page 15

background image

2-6

Gas Connection Pipe Sizes

(Minimum incoming pipe size should be 1 1/2" (41 mm))

Natural

3/4" (22 mm)

1" (28 mm)

1 1/4" (36 mm)

Propane

1/2" (15 mm)

3/4" (22 mm)

1" (28 mm)

Manufactured

1" (28 mm)

1 1/4" (36 mm) 1 1/2" (41 mm)

Gas

Single Unit

2 - 3 Units

4 or more

units*

* For distances of more than 20 feet (6 m) and/or more
than 4 fittings or elbows, increase the connection by one
pipe size.

The Pro H55 Series gas fryer has received the CE mark for the countries and gas categories
indicated in the table below. NOTE: The nominal heat input (QN) is 21kW except for AT, DE, LU
and category 3P/B, which is 23kW.



COUNTRIES CATEGORIES

GAS

PRESSURE

(MBAR)

G20 20

AUSTRIA (AT)

II2H3B/P

G30, G31

50

I2E(R)B

G20, G25

20, 25

BELGIUM (BE)

I3+

G30, G31

28-30, 37

G20 20

DENMARK (DK)

II2H3B/P

G30, G31

30

G20, G25

20, 25

II2Esi3+

G30, G31

28-30, 37

G20, G25

20, 25

FRANCE (FR)

II2Esi3P

G31 50
G20 20

FINLAND (FI)

II2H3B/P

G30, G31

30

G20, G25

20

II2ELL3B/P

G30, G31

50

GERMANY (DE)

I3P G31

50

G20 20

GREECE (GR)

II2H3+

G30, G31

28-30, 37

G20 20

ITALY (IT)

II2H3+

G30, G31

28-30, 37

G20 20

IRELAND (IE)

II2H3+

G30, G31

28-30, 37

G20 20

LUXEMBOURG (LU)

II2E3B/P

G30, G31

50

G25 25

II2L3P

G31 50
G25 25

NETHERLANDS (NL)

II2L3B/P

G30, G31

30

NORWAY (NO)

I3B/P

G30, G31

30

G20 20

PORTUGAL (PT)

II2H3+

G30, G31

28-30, 37

G20 20

II2H3+

G30, G31

28-30, 37

G20 20

SPAIN (ES)

II2H3P

G31 37,

50

G20 20

SWEDEN (SE)

II2H3B/P

G30, G31

30

G20 20

UNITED KINGDOM (UK)

II2H3+

G30, G31

28-30, 37

CE Standard

Required airflow for the combustion air supply is 2m

3

/h per kW.

CE Approved Gas Categories by Country