beautypg.com

FUJITSU CM71-00329-7E User Manual

Page 189

background image

179

CHAPTER2 Dependence Functions

Notes:

A data watch break shares points with the following functions. The maximum number of data
watch breaks varies depending on how those functions are used.

- Code break

- Data break

- Trace trigger

- Sequencer

The data watch break may stop if it hits a specified address after a few steps of instructions
following the instruction with data detection access are executed. The program may not stop if it
hits the specified address during the execution of an instruction.