Furuno FCV-1100L User Manual
Page 74

APPENDIX
A-4
PRR LEVEL (0-20, S, 20)
STC (0-10, 0)
GAIN ADJ (-38-+12, +0)
RX BAND (NARROW, STD, WIDE)
TX PULSE (SHORT1, SHORT2, STD, LONG, MANUAL)
PULSE LENGTH (0.2msec-5.0msec, 0.2msec)
TX/RX
HF and LF should be set.
(Continued on the next page)
(Continued from the previous page)
E/S
FREQ CHOICE (Set frequency of high and low frequencies.)
PWR REDUCTION (OFF, ON)
BOTTOM SEARCH (AUTO, LF, HF)
BOTTOM LEVEL (+0, -40 to +0)
AUTO MODE (OFF, CRUISING, FISHING)
DRAFT SETTING DRAFT (+0.0, -15 to +90. Sets draft depth for both
high and low frequencies.)
RANGE SETTING
RANGE1 (16-6000ft, 30ft)
RANGE2 (16-6000ft, 60ft)
RANGE3 (16-6000ft, 120ft)
RANGE4 (16-6000ft, 250ft)
RANGE5 (16-6000ft, 500ft)
RANGE6 (16-6000ft, 1000ft)
RANGE7 (16-6000ft, 1600ft)
RANGE8 (16-6000ft, 3000ft)
M/Z RANGE (16-600ft, 16ft)
B/L RANGE (16-600ft, 16ft)
SPLIT RANGE (OFF, ON)
SYSTEM
SYSTEM SETTING
PICT ADV DIR (LEFT, RIGHT)
DISP DIVISION ( , )
DEPTH SCALE (RIGHT, CENTER, OFF)
DEPTH UNIT (m, ft, fa, hiro, P/B)
FREE SHIFT (ON, OFF)
AUTO SHIFT (ON, OFF)
ZOOM MODE (BOTTOM LOCK, BOTTOM ZOOM,
MARKER ZOOM,DISCRIM-1/2, DISCRIM-1/3)
LANGUAGE (ENGLISH, OTHER)