SP - 2

4. POWER SUPPLY

(1) System Source

100/110/115/200/220/230 VAC:1.5/0.7 A max., 1 phase, 50-60 Hz

5. ENVIRONMENTAL CONDITION (IEC 60945)

(1) Ambient Temperature

-15°C to +55°C (units for protected area)

Analog display: 0°C to +50°C

(2) Relative Humidity

95% at 40°C

(3) Vibration

IEC 60945 adopted

(4) Category of Equipment

Display Unit/Distance indicator/Transceiver Unit:

For protected area

Transducer:

For submerged use, 600 kPa x 12 h

Distributor/Terminal box: For protected area

6. COATING COLOR

(1) Display Unit

Cover: Munsell 2.5GY5/1.5 (light gray), Panel: N3.0 (gray)

(2) Distribution Box

Munsell 2.5GY5/1.5 (light gray)

(3) Transceiver Unit

Munsell 2.5GY5/1.5 (light gray)

(4) Terminal Box

Munsell 2.5GY5/1.5 (light gray)

(5) Analog Display

Munsell 2.5GY5/1.5 (light gray)

7. COMPASS SAFE DISTANCE

(1) Display Unit/Digital Indicator/Digital Distance Indicator

Standard: 0.50 m, Steering: 0.40 m

(2) Transceiver Unit

Standard: 2.05 m, Steering: 1.40 m

(3) Distribution Box

Standard: 3.10 m, Steering: 2.10 m

(4) Terminal Box

Standard: 0.65 m, Steering: 0.45 m

SAFETY PRECAUTION

- There is no unit giving rise to a dose rate > 0.5 mrem/h at 50 mm.

- There is no harmful radiation from the screen.

- All units of this equipment comply with EMC requirements in IEC 60945, as required by IMO

Res. A.813 (19).