Wiring, Thermostat mounting, Wiring guide — heat pump systems – Honeywell FocusPRO TH5000 Series User Manual
Page 5: English
FocusPRO
®
TH5000 Series
5
69-1922EFS—01
ENGLISH
M29386
Wiring
Wiring guide — heat pump systems
Shaded areas below apply only to
TH5320U/TH5220D
or as otherwise noted.
Thermostat mounting
Align the 4 tabs on the wallplate with
slots on the back of the thermostat,
then push gently until the thermostat
snaps in place.
Push excess wire back into
the wall opening.
Plug wall opening with
non-flammable insulation.
Rc
Y
G
R
C
M29381
1H/1C Heat
Pump System
Rc
Power
[1]
R
[R+Rc joined by jumper]
Y
Compressor contactor
C
24VAC common
[3]
O/B
Changeover valve
[7]
G
Fan relay
2H/1C Heat
Pump System
(
TH5220D
only)
[8]
Rc
Power
[1]
R
[R+Rc joined by jumper]
Y
Compressor contactor
C
24VAC common
[3]
O/B
Changeover valve
[7]
G
Fan relay
Aux
Auxiliary heat relay
[12]
E
Emergency heat relay
[12]
L
Sends output when set to Em. Heat
[11]
2H/1C Heat
Pump System
(
TH5320U
only)
[8]
Rc
Power
[1]
R
[R+Rc joined by jumper]
Y
Compressor contactor
C
24VAC common
[3]
O/B
Changeover valve
[7]
G
Fan relay
Aux/E Auxiliary/Emergency heat relay
L
Sends output when set to Em. Heat
[11]
2H/2C Heat
Pump System
(
TH5320U
only)
[9]
Rc
Power
[1]
R
[R+Rc joined by jumper]
Y
Compressor contactor (stage 1)
C
24VAC common
[3]
O/B
Changeover valve
[7]
G
Fan relay
Y2
Compressor contactor (stage 2)
L
Sends output when set to Em. Heat
[11]
3H/2C Heat
Pump System
(
TH5320U
only)
[10]
Rc
Power
[1]
R
[R+Rc joined by jumper]
Y
Compressor contactor (stage 1)
C
24VAC common
[3]
O/B
Changeover valve
[7]
G
Fan relay
Aux/E Auxiliary/Emergency heat relay
Y2
Compressor contactor (stage 2)
L
Sends output when set to Em. Heat
[11]
See
[notes]
on page 4.
Rc
Y
G
Aux
E
L
R
C
M29382
Rc
Y
G
Aux
E
L
R
C
M29383
Rc
Y
G
Y2
L
R
C
M29384
Rc
Y
G
Aux
E
L
R
C
Y2