Power options, Wiring, Terminal designations – Honeywell FocusPRO TH5000 Series User Manual

Page 3: English

background image

FocusPRO

®

TH5000 Series

3

69-1922EFS—01

ENGLISH

M29370

Power options

Keep wires in this

shaded area

Connect

C

for primary AC power

(optional if batteries are installed).

Insert batteries for primary

or backup power.

Remove factory-

installed jumper

only for two-

transformer

systems.

Conventional Terminals:

Rc 24VAC power from cooling

transformer

R

24VAC power from heating
transformer

W

Heat relay (stage 1)

W2 Heat relay (stage 2)
Y

Compressor contactor (stage 1)

Y2 Compressor contactor (stage 2)
G

Fan relay

C

24VAC common. For 2 transformer
systems, use common wire from
cooling transformer.

Heat Pump Terminals:

Rc 24VAC power from cooling

transformer

R

24VAC power from heating
transformer

O/B Changeover valve
Y

Compressor contactor

Y2 Compressor contactor (stage 2)

-

TH5320U

only

G

Fan relay

Aux Auxiliary heat relay*
E

Emergency heat relay*

L

Sends output when set to Em. Heat

C

24VAC common

*Aux and E terminals combined on

TH5320U

only.

Wiring

Terminal designations

Shaded areas below apply only to

TH5320U/TH5220D

or as otherwise noted.

TH5110D

Rc

Y

W

G

R

C

TH5220D

Rc

Y

W

G

W2

Y2

R

C

TH5320U

Rc

Y

W

G

W2

Y2

R

C

TH5110D

Rc

Y

O/B

G

R

C

Rc

Y

G

Aux

E

L

R

O/B

O/B

C

TH5220D

Rc

Y

G

Aux

E

Y2

L

R

C

TH5320U

M29371

This manual is related to the following products: