CLEARANCE DIMENSIONS

Note #1

To eliminate the risk of burns or fire by reaching
over heated surface units, cabinet storage
space located above the surface units should be
avoided. If cabinet storage is to be provided, the
risk can be reduced by installing a rangehood
that projects horizontally a minimum of 5" (127mm)
beyond the bottom of the cabinets.

Note #2

D

=36" (914mm) minimum clearance between

the top of the cooking surface and the bottom
of an unprotected wood or metal cabinet; or

D

=30" (762mm) minimum when bottom of

wood or metal cabinet is protected by not
less than 1/4"-thick flame retardant millboard
covered with not less than No. 28 MSG sheet
steel, 0.015"-thick stainless steel, 0.024"-thick
aluminum, or 0.020"-thick copper.

Other notes:

z

This range may be installed directly adjacent
to existing 36" (914mm) high base cabinets.

z

If the range is to be placed adjacent to cabinets,
the clearances shown are required. The same
clearances apply to island installations.

z

The range can be placed in various positions
with respect to the cabinet front, with the
control panel either flush or projecting,
depending on the cabinetry depth.

z

The electrical and gas supply should be within
the zones shown in the following diagrams.

z

Any openings in the wall behind the range and
in the floor under the range must be sealed.

z

Always keep the appliance area clear and
free from combustible materials, gasoline and
other flammable vapors and liquids.

z

Do not obstruct the flow of combustion and
ventilation air to the unit.

ISO

FRONT

CLEARANCE DIMENSIONS

OR36S GAS GAS

OR36S DUAL FUEL

INCHES

MM

INCHES

MM

A

Width of ventilation hood installed above range

min 36

min 914

min 36

min 914

B

Vertical distance between countertop and cabinet extending above counter

min 18

min 457

min 18

min 457

C

Clearance from left and right edge of range to nearest vertical combustible surface

min 11 13/16

300

min 11 13/16

300

D

Clearance from cooking surface to:

z

Overhead cabinet centered above the cooktop (combustible/unprotected)*

z

Overhead cabinet centered above the cooktop (non-combustible/protected)*

z

Ventilation hood** centered above the cooking surface

See notes #1 and #2.

min 36

min 30
min 30

min 914

min 762
min 762

min 36

min 30
min 30

min 914

min 762
min 762

E

Depth of overhead cabinetry

max 13

max 330

max 13

max 330

F

Width of cabinetry opening

36

914

36

914

G

Height of cabinetry immediately adjacent to the range
(from floor to countertop)***

max 37 1/2

max 953

max 37 1/2

max 953

H

Depth from wall to cabinetry face

max 25 1/4

max 641

max 25 1/4

max 641

*Non-combustible surfaces:as defined in
‘National Fuel Gas Code’ (ANSI Z223.1, Current
Edition). Clearances from non-combustible materials
are not part of the ANSI Z21.1 scope and are not
certified by UL.
**Refer to local/national codes for
ventilation requirements.
***Depending on the height of the feet adjustment.