LEICA 10x42 Geovid R Binocular/Rangefinder (Yards) User Manual
Page 42
40
DISpLAYING THE ATMOSpHERIC CONDITIONS
2 5 C
1 0 3 0
1 5
For precise calculation of the point of impact (see next
section) the Leica Geovid HD-B determines three
other important pieces of information during the range
measurement: the inclination of the binoculars, the
temperature and the atmospheric pressure. The
relevant values can be displayed at any time.
Briefly press the secondary / menu button (8) once.
•
The reticule appears briefly (if range measurement
was not already active). The following are then
displayed alternately instead of the range for
around 2s:
– Angle of inclination
– Temperature
– Atmospheric pressure
Note:
If the housing of the Leica Geovid HD-B initially has a
significantly different temperature than its
surroundings, e.g. when taking it outside, it can take
up to 30 minutes before the internal sensor can
determine the correct ambient temperature.