11.1.2. Step buttons settings
CC mode
Range
Default settings
CC
0-127
Varies
MIDI channel
USER, 1-16
User
MIDI ports
USB, MIDI, USB&MIDI
USB&MIDI
Min range
0-127
0
Max range
0-127
127
Play mode
GATE/TOGGLE
Gate
MIDI Note mode
Range
Default settings
MIDI note
0-127
Varies
MIDI channel
USER, 1-16
User
MIDI ports
USB, MIDI, USB&MIDI
USB&MIDI
Note Off Velocity
0-127
0
Note On Velocity
0-127
127
Play mode
GATE/TOGGLE
Gate
Program Change mode
Range
Default settings
Program Number
0-127
Varies
MIDI channel
USER, 1-16
User
MIDI ports
USB, MIDI, USB&MIDI
USB&MIDI
Bank LSB
0-127
0
Bank MSB
0-127
127
NRPN mode
Range
Default settings
Bank MSB
0-127
127
Bank LSB
0-127
0
Data
0-127
Varies
MIDI channel
USER, 1-16
User
MIDI ports
USB, MIDI, USB&MIDI
USB&MIDI
127